1000 BH - 1000 EH - 1000 YH
Batteries: removal
When removing the batteries, the operator must be equipped with suitable personal protec-
tion devices (gloves, goggles, overalls, safety shoes, etc.) to reduce the risk of injury. Make
sure the switches on the control panel are in the "0" position (off) and the machine is turned
off. Keep away from naked flames, do not short circuit the battery poles, do not cause sparks
►
Disconnect the battery cables and bridge terminals from the battery poles.
►
If necessary, remove the devices fixing the battery to the base of the machine.
►
Lift the batteries from the compartment using suitable lifting equipment.
Choosing a battery charger
Make sure the battery charger is compatible with the batteries to be charged.
Tubular lead batteries: an automatic charger is recommended. Consult the battery charger manu-
facturer and manual to confirm the choice.
Gel batteries: use a charger specific for this type of battery.
Preparing the battery charger
If you wish to use a battery charger not provided with the machine, you must fit it with the connector
supplied with the machine.
Proceed as follows to fit the connector.
Remove about 13 mm of protective sheath from the red and black cables of the battery charger.
Insert the wires into the connector contacts and squeeze them forcefully with suitable pliers.
Respect the polarity (red wire + black wire –) when inserting the wires into the connector.
Preparing the engine (BH and YH versions)
►
Fill the fuel tank.
►
Check the engine oil level.
Preparing the hydraulic circuit (BH version)
►
Check the hydraulic oil level.
Fitting the side brushes
See the "Replacing/installing the side brushes" section.
Follow the instructions given below to configure the machine's control software to use the
See the "Technical menu" section.
! DANGER!
and do not smoke. Proceed as follows.
! IMPORTANT!
display language you require.
2014-07
English
EN-23