7.
OPTIONAL YOKE LIGHT: To install, slide over the rear leg with LEDs facing in. Push up
onto the housing until tabs are secured. Yoke light will automatically operate when yoke is
energized. To remove, pull sides out and down to disengage tabs, then slide off. No tools
are necessary for installation or removal.
SPECIFICATIONS
Waveform
Magnetic Field (RMS)
Lift Strength
Leg Span / Pole Spacing
Leg / Pole Contact Size
Cord Length
Duty Cycle
Handle Temp at Max Duty Cycle
Ingress Protection (EN60529)
Size
Weight
115V
Electrical
230 V
Environmental
MAINTENANCE
CLEANING
•
Use mild soap and a damp cloth to clean the yoke housing
•
Do not immerse any part of yoke in liquid
•
Legs may be detached at the joints for cleaning
•
Use a rust-preventative spray (LPS-3 or equivalent) on legs for lubrication
DISPOSAL
The Y-2 contains no hazardous materials and complies with EU RoHS regulations. Please
contact your local waste disposal authority for instructions on disposal of electrical waste.
SERVICE
CAUTION
To assure product safety and reliability, repairs should be performed by
Magnaflux Authorized Service Center using original parts.
WARNING
If the yoke housing is opened for any reason, warranty is voided on the unit.
AC
7.1 kA/m at min pole spacing
2.0 kA/m at 5 in / 127 mm spacing
1.4 kA/m at max pole spacing
> 10 lb / 4.5 kg / 44 N
2.5-10.5 in / 6.4-26.7 cm
1.00 x 0.75 in / 25.4 x 19.0 mm
12 ft / 3.6 m
50%, maximum on time 90 sec
< 104°F / 40°C
IP54
9 x 8.25 x 2.25 in / 23 x 21 x 6 cm
4.9 lb / 2.2 kg
6.2 lb / 2.8 kg (with cord)
60 Hz
4.3A maximum
50 Hz
6.3A maximum
50/60 Hz 2.6A maximum
32-120°F (0-49°C), up to 100% RH, up to 16,300 ft
/ 5,000 m altitude, non-condensing