Assembly Instructions
10. Connect the electrical power supply cable in flexible
conduit to wiring compartment.
11. Attach with connectors suitable for conductor size
and ground wiring. After completing the connections,
arrange pigtail unit leads and power supply wires in
wiring compartment.
OPERATING INSTRUCTIONS
HAZARD OF ELECTRIC SHOCK,
EXPLOSION OR ARC FLASH:
• Apply appropriate personal protective equipment
(PPE) and follow safe electrical work practices.
See NFPA 70
• Circuit breaker must be installed and serviced only
by qualified electrical personnel.
• Always use a properly rated voltage device to
confirm power is off.
• Confirm there are no materials near front or
rear grills.
• Switch on the circuit breaker and On/Off rocker switch
to turn on heater. Turn thermostat to furthest clockwise
position. Fan will begin heating the room.
• Select a thermostat setting. Ambient temperature is
regulated by adjusting the thermostat to a desired
position. Allow unit to operate and warm the room.
When desired temperature is reached, turn control knob
counterclockwise until heater turns off. The heater will
start automatically when the room temperature drops
below this set point and will turn off when set point is
reached. The fan will remain on.
• Adjust thermostat with each use.
• To turn off heater, position the On/Off rocker switch
and circuit breaker to Off.
SAFETY TIP-OVER SWITCH
All Models are designed to automatically shut off when
heater is tipped sideways. Place unit on level surface to
prevent tipping.
OVERHEAT & RESET
MODELS 653558, 653673, 653670, 653671,653672,
653566, 653567, 653568 & 653569
These heaters have thermal cut-off protection. If the
thermal cut-off protection trips:
Turn off the power. Turn Off the circuit breaker.
The unit should reset automatically after 10 minutes.
MODELS 653674 & 246068
This heater has Manual reset thermal cut-off protection. If
the thermal cut-off protection trips:
Turn off the power. Turn Off the circuit breaker. Let the
unit cool down for 15 minutes.
Then follow the Manual reset procedure to reset the
thermal cut-off.
1.Open the cover of connection compartment.
2.Identify the Manual reset thermal cut-off with square red
button as follow.
Electric Blower Heater
Salamander Heater
3.Press the red button to reset the thermal cut-off.
If the thermal cut-off protection trips again, consult a
certified electrician to determine the reason of overheating.
MAINTENANCE AND CLEANING
All servicing or maintenance should be performed by
qualified service personnel.
Prior to maintenance be sure to:
1. Disconnect power supply at source.
2. Wait 60 minutes to ensure heating element is cool.
Routine Maintenance:
1. Do not spray or use cleaning liquids or other chemicals
on unit.
2. Interior dust can often be removed with a vacuum
cleaner and crevice tool attachment.
3. To clean enclosure, use a clean, soft and lightly damp
cloth to gently wipe off dirt from surface. Be sure not
to wet heating element or switches. Allow unit to dry
completely before restarting.
WARNING
!
This unit must only be used with the provided floor
stand or optional ceiling bracket. Heater must be
installed with the power switch at the top of the unit.
CAUTION
!
Do not allow water to run into the interior of the
heater as this could cause a fire, an electric shock
hazard and damage the unit.
7