Electrical connection
The electrical connection must comply with national and local regulations and may only be carried out
by an authorized person.
The connection values are stated on the type plate of the heater.
Connect the supplied discharge temperature sensor to terminals 7 and 8, according to the electrical
diagram.
Connect the ERV and heater according to the diagram below.



Operation

The heater must be activated in the menu of the ERV.
Settings via touch screen
0: Turn on touch screen by operating the on / off button
1: Press the mode button for 6 seconds.
2: Operate SET until you see the parameter as 01.
3: Now press MODE once and use the arrows to adjust the
parameter value until it displays 1.
4: You have finished adding the reheater, return to the main menu
by pressing the ON / OFF button.


   


































