Technical Data - Zibro A2W300 Manuel D'utilisation Et D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

J

TEChNICAL DATA

TEChNICAL DATA
Capacity
Nominal power consumption
COPt*
Power supply
Water tank Volume
Nominal Current
Max. Current
Outlet water temperature
(When using heat pump only)
Max. water temperature (when
using E-heater)
Air flow (nom.)
Operating temp. range
Heat pump only mode.
Operating temp. range
E-heater mode only mode.
Refrigerant pressure suction
discharge
Refrigerant pressure suction
(min.) / discharge (max.)
Compressor
Max. tank pressure
Anti legionella function
Magnesium anode
Inside body material of tank
Heat pump heat exchanger material
Secondary heat exchanger material
Refrigerant type/charge
Net Weight empty/full
Sound pressure level
Unit protection class
* According to: EN255-3:1997, incoming water 15°C, exhaust air 20°C,
** Related to electrical heater
4
54
outlet hot water 45°C, including tolerance for COP as mentioned in
EN14511-2:2007.
A2W300
W
2800 (1500**)
kW
0.7 (+1.5**)
W/W
4.0
V/Ph/Hz
230/1/50
L
300
A
4.3 (+6.6**)
A
16
°C
55
°C
70
m³/h
650
°C
+5 - 43
°C
-15 - 43
MPa
0.7 / 3.5
MPa
1.3 / 4.2
Rotary
MPa
1.0
yes
yes
Stainless steel 304
Copper
Stainless steel 304
g
R410A/700
kg
100/400
dB (A)
48
IP
IP XI

Hide quick links:

Publicité

Table des Matières
loading

Table des Matières