f
pARAMETER LIST
G
Adjusting parameters which are marked as "Do not change" should not
be adjusted. Otherwise malfunction of the heat pump boiler may occur.
The warranty does not cover damage by incorrect setting of parameters.
parameter
Description
No.
0
Hot water set temperature
Temperature difference
1
between inlet / outlet hot water
Electric heater hot water set
2
temperature
3
Electric heater delay time
Weekly disinfection
4
temperature.
High temperature disinfection
5
time.
6
Defrosting period.
Defrosting entry coil
7
temperature.
8
Defrosting exit coil temperature.
9
Max defrosting cycle period
Electronic expansion valve
10
adjustment.
11
Target over-heat degree.
Steps of manually adjusting the
12
electronic expansion valve.
Disinfection start up time
13
adjusting.
A
Inlet water temperature
B
Outlet water temperature
C
Evaporator coil temperature
D
Return gas temperature
E
Ambient temperature
F
Electronic expansion valve step.
Range
Default
10 ~ 70°C
55°C
5°C
10 ~ 70°C
55°C
30 min
70°C
30 min
45 min
-7°C
13°C
8 min
1
5°C
35 steps
00.00~23.00
23.00
Adjustable(hour)
°C
°C
°C
°C
°C
Remarks
Adjustable
Do not change
Adjustable
Do not change
Do not change
Do not change
Do not change
Do not change
Do not change
Do not change
Do not change
Do not change
Do not change
4
49