Operation
Place the device on a sturdy, even surface. Plug the power cable into the protective contact cold device connector socket on the
rear side, the other end into a protective contact power socket supplying AC 230 V. Switch on the device by pressing the main
power switch (2) (I = ON / 0 = OFF). The power-LED (7) lights up in red. The device is now operational.
Voltage setting of the outputs
1.
Turn the control AMPERE (6) clockwise until the red LED for current limiting (8 or 13) belonging to the output goes off and
the green LED for voltage limiting (7) lights up.
2.
Now use the VOLT control (5) to adjust the desired output voltage (clockwise higher/counter-clockwise lower). The voltage
available at the respective output socket (3) is displayed in the corresponding 'V' display (4).
3.
Devices use display sharing if they have fewer displays than DC power outputs. In the respective cases, use the pushbutton
(11) to switch for reading values from different outputs. Hold the button down as long as you wish to see the values of
respective values in the display. (Letters give the correspondence between output, display or pushbutton. Refer to the list
of Controls).
Setting current limiting of the outputs
1.
Turn down the controls AMPERE (6) counter-clockwise (the red LED for current limiting (8) lights up and the green LED for
voltage limiting (7) goes off.
2.
Short-circuit the safety connection output sockets (3) of the respective outputs using a suitable cable (connect + with – poles
of the same output).
3.
Now use the AMPERE controls (6) to adjust the maximum current required (clockwise higher/counter clockwise lower). The
current available at the respective output socket (3) is displayed in its corresponding display 'A' (4). (Lettering gives the
correspondence between output, display, or pushbutton). Use pushbutton (11) to switch shared displays for their respective
outputs as is necessary (Refer to list of Controls).
4.
Devices use display sharing if they have fewer displays than DC power outputs. In the respective cases, use the pushbutton
(11) to switch for reading values from different outputs. Hold the button down as long as you wish to see the values of
respective values in the display. (Letters give the correspondence between output, display or pushbutton. Refer to the list
of Controls).
5.
Turn the power supply off by flipping the power switch (2).
6.
Do not remove the short circuitry from the output socket (5) before the device is turned OFF. After removal you can connect
the loads.
7.
Turn the power on again by flipping the power switch (2). Current limiting is now active so that maximum output current
cannot exceed the limit as previously set.
Observe that the current limiting function is not available for fixed current outputs! Fixed current outputs are easily recognizable
because they have no current limiting control. Their voltage control has a smaller external diameter.
Connecting loads
1.
Establish that the total of loads if connected would not exceed the maximum permissible load of the device. If you do not use
the device for some time, please disconnect the mains power supply.
2.
Ascertain that the loads are switched off.
3.
Verify that an appropriate output voltage is set.
4.
Set the current limiting to the value required (See above).
5.
Connect the positive poles (+) of the load to the red (+) connection terminals of the device (3), connect the negative poles (-)
of the load to the blue (-) connection terminals (3).
6.
Use connection cables of sufficient dimension with standard plugs, or standard laboratory power leads.
7.
Earth the loads on the DC outputs via the connection socket (colour-coded in yellow/green).
Make sure that the loads are always switched off when being connected to the power supply. Sparks may be
generated when a load that has been switched on is connected to the terminal screw connectors. This may damage
the terminal screw connectors as well as the connected cables.
14
Entretien
Entretien général
Mettez toujours l'appareil secteur hors service. Avant de nettoyer l'appareil, débranchez le du secteur! Essuyez uniquement
l'appareil avec un chiffon antistatique sec. N'utilisez pas de produits abrasifs ou de solvants!
Changement de fusibles
Mettez l'appareil secteur hors service; et retirez tous les câbles de branchement de l'appareil. N'oubliez pas de débrancher la
fiche secteur de la prise de courant avant de remplacer un fusible.
1.
Enfoncez légèrement le porte-fusible (16) se trouvant à l'arrière à l'aide d'un tournevis à tête cruciforme appropriée et
dévissez celui-ci d'un quart de tour dans le sens contraire aux aiguilles d'une montre (fermeture baïonnette).
2.
Remplacez le fusible défectueux par un nouveau fusible fin du même type et possédant la même intensité nominale (à ce
sujet, veuillez vous référer au point « Caractéristiques techniques »).
3.
Revissez le porte-fusible en exerçant une légère pression avec le tournevis en le tournant dans le sens aux aiguilles d'une
montre.
* Remarque : Les fusibles sont des pièces détachées qui ne sont pas couvertes par la garantie!
Dérangements
Défaut
L'appareil ne fonctionne pas : Les affichages sont éteints.
Pas de tension secteur?
Les consommateurs branchés ne fonctionnent pas.
Elimination des déchets
Mise au rebut d'équipements électriques et électroniques
Afin de respecter l'environnement et de recycler au maximum les objets usagés, il est demandé à l'utilisateur de
rapporter les appareils à mettre au rebut aux points de collecte et de recyclage appropriés.
Le logo représentant une poubelle à roulettes barrée d'une croix signifie que ce produit doit être apporté à un point
de collecte et de recyclage des produits électroniques pour que ses matières premières soient recyclées au mieux.
Vous respecterez ainsi vos obligations civiles et contribuerez à la protection de l'environnement !
Remèdes possibles
1. Contrôlez l'aptitude au fonctionnement du branchement
secteur (prises, fusibles, disjoncteurs-protecteurs, etc.).
2. La tension secteur correcte existe-t-elle?
1. Contrôlez la polarité sur le raccord DC (5).
2. Réduisez la charge de l'appareil secteur par les
consommateurs.
3. Contrôlez les données techniques des consommateurs.
4. Contrôlez si la limitation de courant est active.
23