In case of:
devices fitted with cables without a plug: the type of plug to use is a ''standardised'' one.
The wires must be connected as follows: yellow-green for grounding, blue for neutral
and brown for the live. The plug must be connected to an adequate safety socket.
fixed equipment not provided with a power supply cable and plug, or any other device
that ensures disconnection from the electrical mains, with an opening gap of the con-
tacts that enables total disconnection in overvoltage category III conditions.
Said disconnection devices must be provided in the mains power supply in compliance
with installation regulations.
The Ground cable must not be cut off by the switch.
The Manufacturer declines all responsibility for failure to comply with the safety regulations.
FUMES DISCHARGE
EXTERNAL EXHAUST HOOD (SUCTION)
In this version the fumes and vapours are discharged outside through
the exhaust pipe.
To this end, the hood outlet fitting must be connected via a pipe, to an
external output.
The outlet pipe must have:
• a diameter not less than that of the hood fitting.
• a slight slope downwards (drop) in the horizontal sections to prevent condensation from
flowing back into the motor.
• the minimum required number of bends.
• the minimum required length to avoid vibrations and reduce the suction performance of
the hood.
You are required to insulate the pipes if it passes through cold environments.
In the presence of motors with 800m
external air flowing back.
HOOD WITH INTERNAL RECIRCULATION (FILTERING) (OPTIONAL)
In this model, air passes through the active carbon filters HP (optional) to be
purified and is then recycled into the environment.
Ensure that the active carbon filters HP are assembled into the hood, if
not, install them as indicated in the assembly instructions.
In this version the check valve must not be assembled: remove it if it is on the air
outlet fitting of the motor.
ASSEMBLY INSTRUCTIONS
intended only for qualified personnel
The hood can be installed in various configurations.
The generic assembly steps apply to all installations; for each case, follow
the specific steps provided for the required installation.
OPERATION
WHEN TO TURN ON THE HOOD?
Switch on the hood at least one minute before starting to cook to direct fumes and vapours
towards the suction surface.
After cooking, leave the hood operating until complete extraction of all vapours and odours.
By means of the Timer function, it is possible to set auto switch-off function which will allow
the hood to turn off automatically after 15 minutes of operation.
WHICH SPEED IS TO BE SELECTED?
1st speed: maintains the circulation of clean air with low electricity consumption.
2nd speed: normal conditions of use.
3rd speed: presence of strong odours and vapours.
4th speed: rapid disposal of odours and vapours.
WHEN SHOULD THE FILTERS BE WASHED OR REPLACED?
The metal filters must be cleaned every 30 hours of operation.
The HP active carbon filters (optional), must be reactivated every 3-4 months, depending
on the use of the hood.
For further details see the "MAINTENANCE" chap.
3
/h or higher, a check valve is present to prevent
TOUCH PUSHBUTTON PANEL
ON/OFF (Blue led steady on)
Motor on/off and Speed 1
ON/OFF (blue led flashing)
If pressed for more than 3 seconds, it activates the 24h cycle (1h ON -> 3h
OFF -> 1h ON)
the function deactivates if:
- The motor turns off (key
- After 24h
Speed 2 activation
Speed 3 activation
Speed 4 is only active for a few minutes, then speed 3 activates.
Light on/off
TIMER
(red LED flashing)
Auto switch-off after 15 min.
The function deactivates (red LED off ) if:
- The motor turns off (key
- The speed is changed.
USING THE RADIO CONTROL (OPTIONAL)
WARNINGS!:
Place the hood away from sources of electromagnetic
waves (e.g. microwave ovens), which could interfere
with the radio control and with the hood electronics. The maxi-
mum operating distance is 5 metres, that may vary according to
the presence of electromagnetic interferences.
Radio control operated at 433.92MHz.
The radio control consists of two parts:
- the receiver built into the hood;
- the transmitter shown here in the figure.
DESCRIPTION OF TRANSMITTING COMMANDS
UP
Motor switch-on and speed increase from 1 to 4. Speed 4 is only active for a
few minutes.
DOWN
Speed decrease and motor switch-off.
Light ON-OFF
TIMER ON: The motor automatically switches off after 15 min.
The function is automatically disabled if the motor is switched off (
Command transmission active
RADIO CONTROL CODE CHANGE
With only one radio control, go directly to point 2.
With several radio controls in the same room, a new code can be created by following the
procedure below.
Disconnect the power to the hood before starting the procedure.
1) - CREATE A NEW CODE
The procedure is to be carried out on the radio control.
• Press LIGHT
and TIMER
• Press DOWN
on the radio control: saving is confirmed by three brief flashes of the
display. The new code cancels and replaces the previous default code.
10
)
).
simultaneously until the display starts flashing.
key)