Mitsubishi Electric Mr. Slim PLA-ZM EA Série Manuel D'installation page 5

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 41
3. Installing the indoor unit
950 D
20 – 45
860 – 910 C
795 B
145
193
222
G
F
E
Fig. 3-2
F
D
60
271
357
E
C
Fig. 3-3
20 – 45
145
840 A
E
F
Min. 1500
H
Floor
A
B
Models
C
ZM35, 50
76
ZM60-140
79.5
3.2. Ceiling openings and suspension bolt installation
locations (Fig. 3-2)
Warning:
• This unit should be installed in rooms which exceed the floor space specified
in outdoor unit installation manual.
Refer to outdoor unit installation manual.
• Install the indoor unit at least 2.5 m above floor or grade level.
For appliances not accessible to the general public.
• Refrigerant pipes connection shall be accessible for maintenance purposes.
• Using the installation template (top of the package) and the gauge (supplied as an
accessory with the grille), make an opening in the ceiling so that the main unit can
be installed as shown in the diagram. (The method for using the template and the
gauge is shown.)
* Before using, check the dimensions of template and gauge, because they
change due to fluctuations of temperature and humidity.
* The dimensions of ceiling opening can be regulated within the range shown in
Fig. 3-2; so center the main unit against the opening of ceiling, ensuring that the
respective opposite sides on all sides of the clearance between them becomes
identical.
• Use M10 (3/8") suspension bolts.
* Suspension bolts are to be procured at the field.
• Install securely, ensuring that there is no clearance between the ceiling panel &
grille, and between the main unit & grille.
A Outer side of main unit
B Bolt pitch
C Ceiling opening
D Outer side of Grille
* Note that the space between ceiling panel of the unit and ceiling slab, etc. must be
7 mm or more.
*
When the optional multi-functional casement is installed, add 135 mm to the
dimensions marked on the figure.
Models
ZM35-60
241
ZM71-140
281
3.3. Refrigerant and drainage piping locations of indoor
unit (Fig. 3-3)
The figure marked with * in the drawing represent the dimensions of the main unit
excluding those of the optional multi function casement.
A Drain pipe
B Ceiling
C Grille
D Refrigerant pipe (liquid)
E Refrigerant pipe (gas)
F Main unit
* When the optional multi-functional casement is installed, add 135 mm to the
dimensions marked on the figure.
(mm)
D
76.5
79.5
E Grille
F Ceiling
G Multi functional casement (option)
H Entire periphery
(mm)
A
B
258
298
en
3

Publicité

Table des Matières
loading

Table des Matières