GB
DIP-SWITCH CONFIGURATION
Function
n.
Off On
Input mode
1
Stepping and
Radio Channel
2
(CH1)
3
Barrier speed
4
5
Preflash
Re-closure
6
Timer
7
Not used
SLAVE
8
Operation
Output US1
9
(multipurpose)
mode). Clean
10
contact
Black out
11
opening
Closure
12
photocell
SAFETY DEVICE DISABLING DIP-SWITCHES
Function
n.
Off On
1
FT
2
STP
3
CC
TPR
4
34
Description
Opens-Stops-
During opening, press the P/P button to stop the barrier; press again to close.
Closes
During closure, press the P/P button to stop the barrier; press again to open.
If the P/P button is pressed during opening, the barrier stops then closes.
Opens-Closes
If it is pressed during closure, the barrier stops then opens.
Pressing the P/P button during opening has no effect. Pressing the P/P button during a pause has no
Always opens
effect.
"Condominium"
If the P/P button is pressed during closure, the barrier stops for a few seconds then opens.
Opens-Closes
Pressing the P/P button during opening has no effect. If the P/P button is pressed during a pause,
with no reversal
the barrier closes. if the P/P button is pressed during closure, the barrier stops for a few seconds
during opening
then opens.
high
opening time 3 sec. approx.
medium-high
opening time 4 sec. approx.
medium-low
opening time 6 sec. approx.
low
opening time 8 sec. approx.
Off
The flashing light operates together with the motor.
The flashing light operates 5 seconds before any operation.
On
Off
After complete opening, the barrier can only be closed by a manual command.
After complete opening, the barrier closes after a programmed pause time.
On
Function disabled
Off
The control unit performs the commands received from a MASTER control unit
On
Courtesy light
This mode can be used to operate a courtesy light.
contact
Access from cycle start a programmable time after closure.
Flashing light
Contact for controlling a flashing light, frequency 2 Hz.
contact
Electric
interlock
Output active during opening, closing and pause.
contact
Barrier status
signalling
Output active with barrier not closed.
contact
Off
Function disabled
The barrier remains open in the event of a blackout. When the power returns the barrier closes if
On
dip 6 is ON.
Off
Function disabled.
Tripping of the photocell reduces the pause time to 2 seconds, regardless of the setting.
On
Description
With photocell installed
OFF
ON
Disables photocell input
With STOP input used
OFF
Disables STOP input
ON
JCC in ON
OFF
JCC in OFF
ON
JCC in OFF
Connect transformer secondary to terminals 3 and 4.
OFF
If mains power fails, the barrier opens (with dip 11 ON and with use of buffer battery).
Function disabled
ON
Notes
Notes
With Close Edge (type 8K2) input used
With Close Edge (type NC) input used
Disables Close Edge input
JCC: item 9 di fig. H