Télécharger Imprimer la page

Telcoma Automations SNAP 4 Instructions Pour L'utilisation Et La Programmation page 32

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 14
GB
LEFT-HAND BARRIER
To convert the barrier from RIGHT-HAND to LEFT-HAND, proceed as follows:
1.
Move the spring from the right-hand to the left-hand position (fig. G1)
2.
Swap the motor wires on the control unit (35 with 36, next page)
3.
Swap wires 14 and 16 (electric limit switch)
Then proceed with installation.
DESCRIPTION OF PARTS (Fig. H)
1
-
23
+
TPR
22
-
Slave
D
+
LDA
-
NC
21
COM
NA
20
C1
19
C2
18
1) Auxiliary circuit fuse 24V (2A fast)
2) Motor fuse 24V (10A fast)
3) Internal LED light connector
4) Motor output 24V
5) Encoder connection terminal board
6) TEST and FCS jumpers
TEST: removing this jumper disables the safety inputs
(item 7) with barrier closed.
FCS: remove this jumper if a safety microswitch is used
on the door (input 26 - NC)
7) Safety device and control system power supply terminal
board
8) Control input terminal board
9) Jumper JCC
10) Safety device disabling dip-switches
11) Functions dip-switches
32
2
TR1
FC1
P/P
PA
FC2
SCHEDA RADIO OC
17
16
15
3
PROG.
STOP
P3
LD1
Reset
RS
14
13
12 11
12) Programming buttons
13) Internal LED light connector
14) Control unit RESET jumper
15) OC2 receiver channel 1 model selection jumper:
P/P: stepping
PA: open command
The second channel is always close command.
16) OC2 receiver connector
17) Opening deceleration regulator trimmer
18) Radio antenna input
19) GROUND connection
20) Motor limit switch input
21) US1 (multi-purpose) output contact
22) Bar lights output, SLAVE and TPR controls
23) Control unit power supply input 24Vdc
P/P
TEST
FCS
FT
STP
CC
TPR
ON
1
P/P
2
3
REG.VEL.
4
PRELAMP.
5
RIC.AUT.
6
JCC
7
SLAVE
8
9
JOLLY
10
11
TPR.OPEN
FotoRIC.
12
10
9
Fig. H
M
4
M
D
5
+
-
+
24V
-
+
6
24FT
-
CSB
7
FCS
FT
STP
CC
C
PC
8
PA
P/P

Publicité

loading