ELECTRICAL CONNECTIONS
+
TPR
-
Slave
D
+
LDA
-
NC
COM
NA
C1
C2
Opening key
C1
Limit switch
C2
closure
Dispositivo
Morsetto n.
1
2
3
4
TPR
5
6
comando SLAVE
7
8
Luci ASTA
9
10
Uscita US1
10
11
Uscita US1
12
TERRA
13
14
Contatto NC
15
16
Contatto NC
17
18
Antenna Radio
19
22
NO button
20
22
NO button
21
22
NO button
27
23
Edge 8K2 / N.C.
27
24
NC button
25
27
NC contact
26
27
N.C. contact
28
29
Auxiliary devices
30
31
Auxiliary devices
32, 33, 34
Encoder
35
36
Motor
PROG.
STOP
TR1
Reset
FC1
P/P
PA
FC2
SCHEDA RADIO OC
FC1
FC2
V
I max
24Vdc
control unit power supply
10 A
24Vac
Power failure
SLAVEC control output
24V
100 mA
BAR lighting
NC multifunction output
NO multifunction output
GROUND contact
OPEN limit switch
CLOSE limit switch
Stepping control
Open command
Close command
Closing edge
Stop command
Closing photocell
Door contact
24Vdc
Photocell power supply
1A max
24Vdc
Power supply
32 - / 33 + / 34 D
Motor output 24V
P3
P/P
ON
LD1
10
11
12
RS
Funzione
Connect to power supply output of power supply box
Connect to transformer secondary
Connect to control unit of second (SLAVE) barrier
Connect to bar LED lights, if installed
Contact data: 8A 230V
Contact data: 8A 230V
Limit switch near open position
Limit switch near closed position
Connect to an antenna for 433 MHz (50 Ohm)
See dip-switch configuration table
Starts of opening of the barrier
Starts closure of the barrier
Input enabled for closur. Option of connecting 8K2 edges (JCC closed) or
an N.C. contact (JCC open). If not used, open JCC and set dip-switch CC
(dip-switch 3 of item 10) ON
Cuts out all functions
If not used, set dip-switch STP (dip-switch 2 of item 10) ON
Reverses direction during closure.
If not used, set dip-switch FT (dip-switch 1 of item 10) ON
Connect this input to the door safety microswitch
If not used, place a jumper across the input (wire between 26 and 27)
Power only present when barrier is not closed
Permanent voltage
32 BLUE, 33 GREEN, 34 WHITE
Connection to motor
+
24V
-
+
TEST
24FT
FCS
-
FT
CSB
STP
CC
FCS
TPR
1
FT
P/P
2
STP
3
REG.VEL.
4
PRELAMP.
CC
5
RIC.AUT.
6
JCC
7
C
SLAVE
8
9
JOLLY
PC
TPR
PA
FotoRIC.
P/P
Note
GB
D WHITE wire
+ GREEN wire
- BLUE wire
+
+
Alimentazione
fotocellule
Door contact
FT
STOP
Closing edge
CLOSE button
OPEN button
P/P button
33