Adjusting dispensed volume:
• Activate « settings mode »: (see procedure « Activate settings mode »), unless the settings mode has
already been activated and you haven't cancelled it (with a conventional detection).
• Press the settings buttom twice consecutively (Fig. J): the LED (Fig. I) blinks slowly (for 5 seconds).
• Durings these 5 seconds, place hand beneath the sensor (Fig. J): various doses (0.8ml by default)
are consecutively dispensed. Remove hand when the desired quantity is reached (8 doses maximum).
The new quantity shall be registered and dispensed for all future uses.
The adjustment of the dispensed volume is finished.
MAINTENANCE
The dispenser has not been used for a prolonged period of time:
• Press the settings button 8 times consecutively (Fig. J), to activate pump's priming (which will turn
continuously in the opposite direction).
• Let it turn for about 5 seconds, and press the settings button once again (Fig. J) (the pump will stop,
and return to dispensing mode).
• Run through a few detections to re-prime the pump.
• If at the end of 10 detections, the soap is still not being dispensed, verify that the dispenser does
contain soap:
- If not, fill the tank, and try the detections again.
- If yes, either the pump or the nozzle are blocked. The nozzle can easily be unblocked with a Ø 2mm
(max.) long object, inserted up to 10mm in the nozzle (further could risk damaging the pump).
The LED (Fig. I) is blinking continuously:
• Open the lid (Fig. H) to access the electronic unit.
• Open the hatch (Fig. F).
• Remove the battery case.
• Remove the battery holder from its protection case.
• Change the 6 AA batteries (do not mix new and used).
• Put the battery holder back in its protection case.
• Put the case back in place, and put the wires back
• Close the hatch then the lid (Fig. F and H).
The dispenser is malfunctioning despite the batteries having been replaced:
• Open the lid (Fig. H).
• Dismantle the electronic unit (Fig. G).
• Replace the seal (Fig. G) supplied with the replacement kit for the electronic unit.
• Put the new electronic unit in the place of the old one (Fig. G).
It is recommended that the settings be reset.
MAINTENANCE & CLEANING
• Clean with mild soapy water using a cloth or a sponge.
• Never not use abrasive, scouring powder, chlorine or any other acid-based cleaning products.
For the UK market only: Tel. 01491 821 821 - email: technical@delabie.co.uk
For all other markets: Tel. +33 (0)3 22 60 22 74 - email: sav@delabie.fr
After Sales Care Support:
The installation guide is available on: www.delabie.co.uk
The installation guide is available on: www.delabie.com