OPERATION (Fig. I & J)
• Automatic open and closing via infrared presence detection of hands.
• Before first use, deactivate the « sleep » mode (rotation of the pump every 72hrs in order to prevent wear
of the silicone tube): press the settings button  for 5 sec (Fig. J). The LED  (Fig. I) will blink 5 times.
• To reactivate the « sleep » mode: press the settings button 5 times consecutively , the LED 
will light up for 3 seconds. (For safety, you can check that the product is no longer detecting).
INSTALLATION
• Install the dispenser at least 250mm above the basin (350mm if it's a stainless steel basin).
• In order to avoid interference from infrared waves, do not install reflective objects within the sensor's
field of detection  (Fig. J).
• Electric supply with 6 AA – 1.5 V (DC9V) batteries, supplied in the case.
• Remove the cover  (Fig. G). Fill the tank with liquid soap with a maximum viscosity of 3,000 mPa.s.
• Replace the cover  on the tank, and close the lid (Fig. H).
REMEMBER
• Our products must be installed by professional installers in accordance with current
regulations and recommendations in your country, and the specifications of the fluid engineer.
• Do not shake the dispenser.
• Do not block the soap outlet or the sensor.
SETTINGS
Factory settings:
• Detection distance: 100mm.
• Volume distribution: 1 dose of 0.8ml.
1
possibility: if the lid needs to be opened (e.g. battery replacement, fill tank)
st
• Open the lid (Fig. G), in order to cut off the dispenser supply.
• Wait at least 5 mins and then close lid, without carrying out any other action (detection, pressing
the settings button etc.). The LED will blink 5 times.
• The settings mode is now available until detection of normal use.
• See sections below for different settings.
2
possibility: if the cover does not need to be opened
nd
• Press the settings button for at least 15 seconds  (Fig. F), until the LED blinks quickly.
• Release the settings button.
• The settings mode is now available until detection of normal use.
• See sections below for different settings.
Adjust detection distance:
• Activate « settings mode »: (see procedure « Activate settings mode »), unless the settings mode has
• already been activated and you haven't cancelled it (with a conventional detection).
• Press and hold the settings button for at least 5 seconds  (Fig. J) until the LED  (Fig. I) blinks quickly.
• Release the button, the LED  (Fig. J) will stay lit for up to 2 seconds.
• During this time, place hand at desired distance from the sensor  (Fig. J (between 5 and 15cm),
before the LED switches off.