2. SPECIFICATIONS
2.1 Technical data for the swimming pool heat pump unit
Models
Heating capacity*
Absorbed electrical power *
Running current*
Power supply
aM type fuse calibre
Curve D circuit breaker
Compressor quantity
Type of compressor
Fan quantity
Fan power
Fan rotation speed
Ventilation
Sound pressure level
(at 1 metre)
Hydraulic connection
Nominal water flow*
Water pressure drop (max)
Unit net dimensions (L/l/h)
Net weight per unit
* Value at +/- 5% under the following conditions: Exterior temperature = 15°C (59°F) / HR = 71% /
Water inflow temperature = 26°C (78.8°F).
In accordance with the NF -414 standard (annual use)
2
ENERGYLINE PRO
ENP6MASC
kW
17,8
kW
3,69
A
16,2
V
230V
50Hz
Ph/Hz
A
20
A
20
1
Scroll
2
W
50 — 225
RPM
600 — 950
Horizontal
dB(A)
45
mm
50
m
3
/h
6,6
kPa
7
mm
1138 / 470 / 1264 1138 / 470 / 1264
kg
127
ENP6TASC
ENP7TASC
18,2
3,7
7,69 / 6,89 / 6,33
9,71 / 8,01 / 7,70
400V 3N
50Hz
400V 3N
12
12
1
Scroll
2
50 — 225
50 — 225
830 — 960
800 — 1050
Horizontal
Horizontal
45
50
6,6
7
1138 /470 / 1264
123
23,4
5,15
50Hz
16
16
1
Scroll
2
47
50
8
18
140