6. VEDLEGG
6.1 Koblingsskjemaer
ENP6MASC
KM1
KM-6
CON
N
N
Soft start
COMP-R
KM1
START
COMP-R
COMP
BLK
CC
CR
WHT
CS
RED
C2(35uF)
C1(60uF)
C3
(161~193uF)
TO POWER SUPPLY
230V
/50Hz
MERKNADER:
1. AT : SENSOR FOR LUFTTEMPERATUR
2. COMP : KOMPRESSOR
3. CT : SENSOR FOR FORDAMPET TEMPERATUR
4. EEV : ELEKTRONISK EKSPANSJONSVENTIL
5. FM1-2 : VIFTEMOTOR
6. FS : VANNSENSOR
7. HP : HØYTRYKKSBRYTER
8. IT : TEMPERATURSENSOR TIL VANNINNLØP
9. LP : LAVTRYKKSBRYTER
20
1
L1
3
2
4
CH
OUT3
L1
N1
1
3
5
7
02
2
4
6
8
OUT4
KM1
OUT5
AC-N
FILTER
L
N
RED BLU
L N
2
2
TC
12V
5
7
04
4V
6
8
1
4V
2
EEV
5
OUT1
OUT2
FS
LP
HP
Controller
10. OT : TEMPERATURSENSOR TIL VANNUTLØP
11. SUT : SENSOR FOR SUGETEMPERATUR
12. TC : OMFORMER 230V
13. 4V : 4-VEIS VENTIL
14. KM1 : EFFEKTKONTAKTOR
15. SOFT STARTER : ELEKTRONISK STARTER
16. CH : BUNNKASSEVARMER
17. ET : TEMPERATURSENSOR FOR UTLADNING
18. OUT2 : POTENSIALFRI KONTAKT, MAKS. 7A
P1
P2
OUT2
3
5
N1
7
03
4
6
8
50K
ET
GND
t
ET
AI06
5K
AT
GND
t
AT
AI05
5K
CT
GND
t
CT
ACN
AI04
5K
OT
GND
ACL
t
OT
AI03
L3
5K
IT
GND
t
N1
IT
AI02
5K
L5
SUT
GND
t
SUT
AI01
+5V
GND
FM1
3
WIFI
/ 12V
CN1
CN4
PRS2 PRS1
NET2
TP2
TP1
3
FM2