Location Requirements - Whirlpool JENN-AIR JXI5036WS Instructions D'installation Et Guide D'utilisation Et D'entretien

Hotte de cuisinière jenn-air® en îlot de 36" et 42" (91,4 cm et 106,7 cm)
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

For non-vented (recirculating) installations, you will also need:
Recirculation Kit Part Number W10272065 for non-vented
(recirculating) installations only. See "Assistance or Service"
section to order.
Parts supplied
Remove parts from packages. Check that all parts are included.
Hood canopy assembly with ventilator and light bulbs
installed
8 vertical supports
2 - glass mounting brackets
Glass mantle
Mounting template
Upper horizontal support
Horizontal support
58 - 4 x 8 mm screws
4 - 3.5 x 9.5 mm glass mantle mounting screws
4 - 5 x 45 mm screws
4 - 3 x 6 mm screws
2 - Upper vent covers
2 - Lower vent covers
4 - Plastic clips

Location Requirements

IMPORTANT: Observe all governing codes and ordinances.
Have a qualified technician install the range hood. It is the
installer's responsibility to comply with installation clearances
specified on the model/serial rating plate. The model/serial rating
plate is located behind the left filter on the rear wall of the vent
hood.
Canopy hood location should be away from strong draft areas,
such as windows, doors and strong heating vents.
Cabinet opening dimensions that are shown must be used. Given
dimensions provide minimum clearance.
Grounded electrical outlet is required. See "Electrical
Requirements" section.
Because of the size and weight of this island hood, the chimney
support must be securely attached to the ceiling.
For plaster or drywall ceilings, the chimney support must be
attached to joists. If this is not possible, you must build a
support structure behind the plaster or drywall. The support
structure must be able to support 80 lbs (36.6 kg).
This range hood is recommended for use with cooktops with
a maximum total rating of 60,000 BTUs or less.
The range hood is factory set for venting through the roof or wall.
For non-vented (recirculating) Installation see "Non-vented
(recirculating) Installations" in "Install Range Hood" section.
Recirculation Kit Part Number W10272065 is available from your
dealer or an authorized parts distributor.
All openings in ceiling and wall where range hood will be installed
must be sealed.
For Mobile Home Installations
The installation of this range hood must conform to the
Manufactured Home Construction Safety Standards, Title 24
CFR, Part 328 (formerly the Federal Standard for Mobile Home
Construction and Safety, Title 24, HUD, Part 280) or when such
standard is not applicable, the standard for Manufactured Home
Installation 1982 (Manufactured Home Sites, Communities and
Setups) ANSI A225.1/NFPA 501A, or latest edition, or with local
codes.
4
Product Dimensions
13³⁄₈" (33.8 cm)
*35³⁄₁₆" (99.5 cm) min.
53³⁄₁₆" (152.8 cm) max.
**35³⁄₁₆" (107.0 cm) min.
56³⁄₁₆" (158.0 cm) max.
25¼" (64.0 cm)
1½" (4.0 cm)
36" - 42" (91.4 cm to 106.7 cm)
*Vented installations only
**Non-vented (recirculating) installations only
Installation Clearances
B*
D
A. Ceiling height
B. Hood height from ceiling to bottom of the
range hood: A-C-D=B
C. Hood height: 24" (61.0 cm) min. from
electric cooking surface, 30" (76.2 cm)
min. from gas cooking surface, suggested
36" (91.4 cm) max
D. Countertop height
MPORTANT:
Minimum distance "C": 24" (61.0 cm) from electric cooking
surface.
Minimum distance "C": 27" (68.6 cm) from gas cooking
surface.
Suggested maximum distance "C": 36" (91.4 cm)
15" (38.0 cm)
A
C

Publicité

Table des Matières
loading

Table des Matières