Make Electrical Connection - Whirlpool JENN-AIR JXI5036WS Instructions D'installation Et Guide D'utilisation Et D'entretien

Hotte de cuisinière jenn-air® en îlot de 36" et 42" (91,4 cm et 106,7 cm)
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Range Hood Installation
1. Using 2 or more people, lift the range hood assembly and
attach it by snapping the vertical supports to the spring clips
in the upper horizontal support bracket that is mounted to the
ceiling.
NOTE: The range hood assembly must be held in place while
you are installing the screws in the next step.
2. Install 16 - 4 x 8 mm screws and tighten to secure.
A
A. Mounting screws
Connect Vent System
1. Install vent system.
2. Push duct over the exhaust outlet. Seal all connections with
vent clamps.
3. Use caulk to seal all openings.
Non-Vented (recirculating) Installation
1. Attach the air deflector to the upper horizontal support using
4 mounting screws.
B
A
A. Deflector
B. Mounting screws
2. Measure the length of 8" (20.3 cm) duct (not included)
needed to connect the transition to the deflector.
NOTE: Vent should fit up inside the deflector 1" (2.5 cm)
minimum.
3. Install vent between the transition and the deflector.
NOTE: To make vent installation easier, temporarily remove
the deflector from the chimney support bracket and replace
after vent section is in place.
4. Seal all connections with vent clamps.
8

Make Electrical Connection

Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1. Disconnect power.
2. Remove terminal box cover.
3. Remove the knockout in the terminal box cover and install a
UL listed or CSA approved ¹⁄₂" strain relief.
4. Run 3 wires, black, white and green (14AWG), in ¹⁄₂" conduit
from service panel to terminal box. Use caulking to seal
opening.
B
5. Use UL listed wire connectors and connect black wires (D)
together.
6. Use UL listed wire connectors and connect white wires (F)
together.
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal box.
Failure to do so can result in death or electrical shock.
WARNING
Electrical Shock Hazard
B
A
C
D
E
F
A. UL listed or CSA approved strain relief
B. Home power supply cable
C. Terminal box
D. Black wires
E. Green (or bare) wire connected to yellow-green wire
F. White wires
WARNING
Electrical Shock Hazard

Publicité

Table des Matières
loading

Table des Matières