OPERATION
Before performing a leak test, be sure that no sparks can occur and you are in a spacious outdoor
area. Connect the propane tank to the regulator and turn the valve on the unit to the
position. Brush a soap and water mixture on all connections. Turn the gas supply on. If bubbles
occur on any connection there may be a leak. If you smell gas or a leak is discovered, turn the
gas valve off, disconnect propane tank and do not use the appliance until the leak is
repaired.
Do not use the heating unit without inspecting the gas hose. If there are signs of wear or abrasion,
you must replace the hose (if applicable). Pumice stones/lava rocks/LavaGlass
20 minutes after igniting. Flame height should be a yellow/blue colour between 2 in (5 cm) and 10 in
(25 cm) in height.
Wait 50 minutes after extinguishing flame prior to placing a lid (if applicable) or protective cover on
heating unit.
To Light
1.
Be sure to remove the lid before lighting the fire pit.
2.
To light the fire pit, push and turn the control knob (G) on the side of the body (B)
counterclockwise to ignite the piezo ignition. It may take several attempts to light the ignition.
3. To adjust the flame, turn the control knob (G) either clockwise or counterclockwise depending on
whether you want to lower or raise the flame.
To Extinguish
1.
Push and turn the control knob (G) clockwise to turn off the fire pit.
2
. Close the cylinder valve on the propane tank if you don't intend to use it for a long time.
WARNING
The heating unit and the propane tank must be
kept at a minimum distance of 60 in (1.52 m)
of each other.
WARNING
If the burner does not ignite with the burner
control valve open, gas will continue to flow
out of the burner and could accidentally ignite
causing injury or property damage.
"OFF"