Télécharger Imprimer la page

Hilti HSL-4 Mode D'emploi page 14

Publicité

Les langues disponibles

Les langues disponibles

European Technical Assessment ETA - 1 9 / 0 5 5 6
English translation prepared by CSTB
Table B7: Installation parameters HSL4-B
HSL4-B
Nominal diameter of
drill bit
Max. cutting diameter of
drill bit
Max. diameter of
clearance hole in the
fixture
Setting position
Fixture thickness
Effective fixture
thickness
Reduction of fixture
thickness
Effective anchorage
depth
Min. depth of drill hole
Min. thickness of
concrete member
Width across flats
Installation torque
Uncracked concrete
Minimum spacing
Minimum edge distance
Cracked concrete
Minimum spacing
Minimum edge distance
HSL4-B Safety cap version
Hilti heavy duty anchor HSL4
Intended use
Installation parameters HSL4-B
M12
d
[mm]
18
0
d
[mm]
18,5
cut
d
[mm]
20
f
t
[mm]
5 - 200
fix1
t
fix,i
[mm]
0
25
i
h
[mm] 80
105 130 100 125 150 125 155 185 150 180 210
ef,i
h
[mm] 105 130 155 125 150 175 155 185 215 180 210 240
1,i
h
[mm] 160 225 250 200 275 300 250 380 410 300 405 435
min,i
SW
[mm]
24
T
[Nm]
inst
s
[mm]
80
min
c  [mm]
160
c
[mm]
80
min
s  [mm]
240
s
[mm]
70
min
c  [mm]
140
c
[mm]
70
min
s  [mm]
160
M16
24
24,55
26
10 - 200
- 
1)
t
fix,1
50
0
25
50
0
30
The torque is controlled by the safety cap.
100
240
100
240
80
180
100
200
Annex B7
Page 13 of 29 | 0 3 / 0 6 / 2 0 2 1
M20
M24
28
32
28,55
32,7
31
35
10 - 200
10 - 200
i
30
60
0
30
36
41
125
150
300
300
150
150
300
300
120
120
220
260
120
120
220
280
60

Publicité