Leak Testing Valves, Hoses and Regulator
1. Turn all control knobs to the OFF position.
2. Be sure regulator is tightly connected to LP cylinder.
3. Completely open LP cylinder valve by turning hand wheel
counterclockwise. If you hear a rushing sound, turn gas off
immediately. There is a major leak at the connection. Correct
before proceeding.
4. Brush soapy solution onto areas circled below, or other similar
fittings on your grill.
NOTE:
Sideburner shelf fascia not shown for clarity.
5. If "growing" bubbles appear there is a leak. Close LP cylinder
valve immediately and retighten connections. If leaks cannot
be stopped do not try to repair. Call for replacement parts.
6. Always close LP cylinder valve after performing leak test by
turning hand wheel clockwise.
WARNING
Turn controls and gas source or tank OFF when not
in use.
6
WARNING
For Safe Use of Your Grill and to avoid serious injury:
Do not let children operate or play near grill.
Keep grill area clear and free from materials that burn.
Do not block holes in sides or back of grill.
Check burner flames regularly.
Use grill only in well-ventilated space. NEVER use in
enclosed space such as carport, garage, porch,
covered patio, or under an overhead structure of any
kind.
Do not use charcoal or ceramic briquets in a gas grill.
Use grill at least 3 ft. from any wall or surface.
Maintain 10 ft. clearance to objects that can catch fire or
sources of ignition such as pilot lights on water heaters,
live electrical appliances, etc.
Apartment Dwellers:
Check with management to learn the requirements and
fire codes for using an LP gas grill in your apartment
complex. If allowed, use outside on the ground floor
with a three (3) foot clearance from walls or rails. Do
not use on or under balconies.
NEVER attempt to light burner with lid closed. A build-
up of non-ignited gas inside a closed grill is hazardous.
Never operate grill with LP cylinder out of correct
position specified in assembly instructions.
Always close LP cylinder valve and remove coupling nut
before moving LP cylinder from specified operation
position.

Publicité

Table des Matières
loading

Table des Matières