Reason 3: In cooling mode, the room temperature is lower than the set temperature. So, change the temperaturę level.
Reason 4: In dehumidification mode, the ambient temperature is low. Please do note that the device is placed in a room with an ambient
temperature of greater than 17 ℃ (62 ℉).
Reason 5: The ambient temperature is too low or too high. The intended operation temperature of the device is 7-35 ℃ (44-95 ℉).
Problem II.: The cooling effect is not good.
Reason 1: Direct sunlight. So, drawn the curtains.
Reason 2: Door and windows are open , many heat sources in the room. So, close the door and windows, move out heat sources.
Reason 3: Filters are too dirty. So, clean or replace filters.
Reason 4: Air-inlet or air out-let is blocked. So, remove blockage.
Problem III.: Big Noise
Reason: The device is not placed on a flat surface. So, put the device on a flat and hard place to reduce noise.
Problem IV.: Compressor does not work.
Reason: Compressor time-delay protection turn on. So, wait for 3 minutes until the temperature is lowered, and then restart the machine.
Problem V.: The remote control does not work.
Reason 1: The distance between the machine and the remote control is too far. So, let the remote control get close to the air conditioning,
and make sure that the remote control directly faces to the direction of the remote control receiver.
Reason 2: The remote control is not aligned with the direction of the remote control receiver. So, let the remote control get close to the air
conditioning, and make sure that the remote control directly faces to the direction of the remote control receiver.
Reason 3: Batteries are dead. So, replace batteries.
Problem V.: Display shows: "E1".
Reason: The pipe temperature sensor is abnormal. So, contact professional service for help.
Problem VI.: Display shows: "E2".
Reason: The room temperature sensor is abnormal. So, contact professional service for help.
Note: when abnormal situations are occurred, turn off machine and pull out plug, then contact with professional service for help.
Do not repair the device yourself. Not qualified repair will void the warranty.
TECHNICAL DATA:
Cooling capacity at BTU: 12000 BTU / hour
Cooling capacity in watts: 3520 W
Energy consumption (cooling) in watts: 1350 W
Air flow: 400 m3 / hour
Drying capacity: 28 liters / 24 hours
Energy class: A
Timer: 1-24 hours
Cooling agent: R290, 230 grams
Noise level: < 65dB
Voltage: 220-240 V ~50Hz
Caution, risk of fire.
Do NOT pierce or burn.
Be aware that the refrigerant may not contain an odour.