The menu item Reset can be used to erase all logged data from the internal
memory of the DL3 Datalogger and to reset all adjustments made in the DL3 back
to their factory settings.
To erase all data and reset all adjustments to their factory settings, proceed as
follows:
Î Select the menu item Reset by pressing buttons  and , and confirm with
button .
Î To erase all data and reset all adjustments, confirm the security enquiry Erase?
by selecting Yes and confirming by pressing button .
5.5.9 Version
In order to display the software version, proceed as follows:
Î Select the menu item Version by pressing buttons  and , and confirm with
button .
The current software version is displayed.
5.6

LAN connector

D L3
Made in Germany
-45527 Hattingen
Ser iennummer
Master /Slave
B us 2 V B us 3 V B us 4
V B us 5
V B us 6
3
4
5
6
7
8
9
10
11 12
The integrated LAN connector  is located on the terminal strip of the device. The
LAN connector supports transfer rates of up to 100 MBit per second.
5.7

USB interface

ade in Germany
er iennummer
12V
Master /Slave
V B us 4
V B us 5
V B us 6
1A m ax.
7
8
9
10
11 12
The DL3 is equipped with a USB interface to which the USB adapter cable can be
connected.
32
Datalogger DL3
12V
1A m ax.
L A N
U SB
Datalogger DL3
L A N
U SB
S 1
S 2
In order to connect the USB adapter cable to the DL3, proceed as follows:
Î Connect the USB adapter cable to the interface marked USB.
Note:
Presently, the firmware of the device does not support external USB de-
vices. As soon as USB support becomes possible, it will be made available
via an automatic DL3 Datalogger firmware update.
Menu structure
Adjustment channel Adjustment range / selection
Language
Date and time
Time
-Date
-Time
VBus
-VBus 1 ... VBus 6
HQM
-Activated
-Fluid type
S 1
S 2
S 3
-Cencentr.
-Reset
Sensors
-S1 ... S3
-Type
-Offset
-Vol./Imp.
-Current loop
-Type
S 3
Logging
-Interval
-Log. type
Network
-VBus.net
-LAN
English, Deutsch, Francais, Español, Italiano
01.01.2001 ... 31.01.2050
00:00 ... 23:59
Yes, No
Yes, No
Water, Propyl., Ethyl., Tyfo LS
20 ... 70 %
Yes, No
None, Pt1000, Pt500, KTY, Impulse
-15.0 ... +15.0 K
0.1 ... 100.0 l/Imp
None, 0-20 mA, 4-20 mA, Si-420TC
00:01 ... 20:00 (mm:ss)
linear, cyclic
Yes, No
Factory setting
No
Yes
Water
37 %
None
0.0 K
1.0 l/Imp
cyclic
No