ENGLISH
1.
WARNINGS
Important: Before attempting any work on the control board
(connections, maintenance), always turn off power.
- Install, upstream of the system, a differential thermal breaker with
adequate tripping threshold.
- Connect the earth cable to the appropriate terminal on the J7
connector of the equipment (see fig.2).
- Always separate power cables from control and safety cables
(push-button, receiver, photocells, etc.). To avoid any electric
noise, use separate sheaths or a shielded cable (with earthed
shield).
2.
TECHNICAL SPECIFICATIONS
Power supply
Absorbed power
Motor max. load
Accessories max. load
Operating ambient temperature
Protection fuses
Function logics
Semi-automatic / Safety devices / Semi-automatic B /
Dead-man C / "Stepped" semi-automatic / Mixed Log. B+C
Work time
Pause time
Thrust force
Terminal board inputs
Open / Partial opening / Safety devices at opng. /
Safety devices at clsng. / Stop / Edge / Power supply + Earth
On-connector inputs
Opening and closing limit-switches / Encoder
Terminal board outputs Flashing lamp - Motor - 24 Vdc accessories power
supply - 24 Vdc indicator-light / Timed output. - Fail safe
Rapid connector
5-pin card connection for radio-receiver module
Programming
3 keys (+, -, F) and display, "basic" or "advanced" mode
Basic mode programmable functions Function logic - Pause time - Thrust
Advanced mode programmable functions
Fail safe - Pre-flashing - Indicator-light/Timed output -
Encoder - Decelerations - Partial opening time -
Work time - Assistance request - Cycle counter
4.
ELECTRIC CONNECTIONS
J5
J3
LIMITS
ENCODER
ENCODER
(optional)
LIMIT-SWITCH
CONTROL BOARD SPRINT 382
230 V~ ( +6% -10%) - 50 Hz
10 W
1000 W
0,5 A
-20 °C +55 °C
2 (see fig. 1)
Automatic / "Stepped" automatic /
Programmable (from 0 to 4 min.)
Programmable (from 0 to 4 min.)
Adjustable over 50 levels
Force - Gate direction
Torque at initial thrust - Braking -
Opening and closing safety devices logic -
1
2
3
4
5
6
ACCESSORIES
For connection of the
photocells and safety
devices, see paragraph
PARTIALLY OPEN
TOTALLY OPEN
3.
LAYOUT AND COMPONENTS
DL
+
+
RADIO
J2
FCA
OPEN
B
J2
FCC
OPEN
A
ENCODER
J5
J5
J3
J3
1
LIMITS
ENCODER
DL
SIGNALLING AND PROGRAMMING DISPLAY
Led
INPUTS STATUS CONTROL LED
J1
LOW VOLTAGE TERMINAL BOARD
J2
CONNECTOR FOR
J3
ENCODER CONNECTOR
J5
LIMIT -SWITCH CONNECTOR
J6
MOTORS AND FLASHING LAMP CONNECTION TERMINAL BOARD
J7
230 VAC POWER SUPPLY TERMINAL BOARD
F1
MOTORS AND TRANSFORMER PRIMARY WINDING FUSE (F 5A)
F2
LOW VOLTAGE AND ACCESSORIES FUSE (T 800mA)
F
"F" PROGRAMMING PUSH-BUTTON
–
"–" PROGRAMMING PUSH-BUTTON
+
"+" PROGRAMMING PUSH-BUTTON
-
-
J1
J6
7
8
9 10 11 12
24 Vdc
3 W
4.1.
NB.: The capacitor is supplied with the operator.
10
-
F
–
F
FSW
STOP
OP
Led
FSW
EDGE
CL
SAFE
- -
J6
J1
2
3
4
5
6
7
8
9 10 11 12
J1
ACCESSORIES
RADIO-RECEIVER MODULE
13 14 15 16 17
PE N
MAIN
MOTOR
LAMP
C
M
230 Vac
max. 60W
230 Vac
STOP
F2
F2
F1
F1
J7
13 14 15 16 17
PE N
L
J6
MAIN
J7
MOTOR
LAMP
Fig. 1
J7
L
50 Hz
Fig. 2