Bradley Sentry SN2008 Mode D'emploi page 4

Lavabo fontaine circulaire 54 1372 mm à infrarouge

Publicité

Les langues disponibles

Les langues disponibles

SN2008 - Infrared
Rough-In Dimensions for Supplies and Drain
Notes
Maximum flow rate required to washfountain is 1 .5 GPM . Size supply
lines accordingly .
Supplies from Below: Stub up 2-1/2" (64) .
Supplies from Above: Supplies must be located on centers of
dimensions shown to pass through washfountain shroud and
sprayhead .
Drain through floor: Stub up 3" (76) .
Supplies from Below or Through Wall
3-1/4" (83)
4" (102)
Remote mounting of transformers with 12VDC
electrical supply to washfountain is recommended.
4
Type A
Off-line vent (P-Trap
supplied by Installer .)
Type H
Centrally rising vent (P-Trap
furnished with unit .) Use for units
with paper towel Dispensers
and/or shrouds .
Top View
4-1/2"
4-1/2"
(114)
(114)
H
C
Type H
5"
(127)
Type A
8/21/2017
Key
1/2" Supply: Nominal Copper Tube
1-1/2" NPT Drain Stub up 3" (76) from Floor
Conduit Location (Recommended)
Supplies from Above
Type B
Centrally rising vent (P-Trap
furnished with unit .) Use for units
with paper towel Dispensers
and/or shrouds .
Type O
Off-line vent (P-Trap
supplied by Installer .)
Top View
4" (102)
27/32" (21)
H
5"
27/32" (21)
(127)
C
1-3/16"
(30)
Bradley • 215-1069 Rev. L; ECN 17-00-002
Installation
(mm)
Type B
Type O