USE AND CARE INFORMATION CONTINUED
This rangehood system is designed to remove smoke, cooking
vapors and odors from the cooktop area.
For Best Results
Start the rangehood several minutes before cooking to develop
proper airflow. Allow the unit to operate for several minutes
after cooking is complete to clear all smoke and odors from
the kitchen.
Cleaning
The metal grease filters should be cleaned frequently in hot
detergent solution or washed in the dishwasher. Stainless steel
cleaner should be used on stainless rangehoods. Abrasives
and scouring agents can scratch stainless steel finishes and
should not be used to clean finished surfaces.
Replacing the Lamps
Before attempting to replace the lamps, make sure that the
light switch is turned off. Remove the 2 screws (FIGURE
below) that hold the light support and gently pull the support
down from the hood. Remove the lamp from the light support
and replace with new lamp. Replace the light support and fix
it into place with the 2 screws.
An alternative method to replace the lamps is to use a 1 1/4"
suction cup (FIGURE below). Attach the suction cup to the
bulb and pull firmly down on the bulb and replace with a new
lamp.
Auto On Fan
The range hood is equipped with a sensor to automatically
turn on the fan when excessive heat is detected in the control
area. When the fan switch is in the "Off" position, this sensor
will turn the fan to high speed when necessary. When the heat
decreases,the fan will turn off.
When the fan switch is in the "On" position, the heat sensor is
not active and the range hood functions normally.
Thermal Protector
The range hood is equipped with a thermal protector to avoid
overheating conditions. If the range hood shuts off while in use,
move the fan slider switch to the "Off" position to turn off the
range hood. Wait approximately 60 minutes, then move the fan
slider switch to the "On" position to restart the range hood.
NOTE:
Before cleaning or servicing the range hood, move the fan auto
on switch to the "O" position (sensor Off). The switch is located
behind the filters. See previous page to remove the filters.
When cleaning or servicing is complete, move the fan auto-on
switch to the "I" position (sensor On).
A. Fan auto-on switch (shown in Off position)
Version 06/12 - Page 10