Installation

ESD damage!
ATTENTION!
Electrostatic discharge can lead to damage to electronic com-
ponents!
Î Take care to discharge properly before touching the
inside of the device. To do so, touch a grounded sur-
face such as a radiator or tap!
ATTENTION!
Short circuit!
A short circuit can lead to damage to electronic components!
Î Close the housing before establishing the mains con-
nection!
Do not use the device if it is visibly damaged!
The DL2 Datalogger comes with the mains adapter and the VBus
nected.
The housing does not have to be opened in order to mount the device.
Initial installation must be carried out by the system installer or qualified personnel
named by the system installer.
The controller must additionally be supplied from a double pole switch with contact
gap of at least 3 mm.
18
4.1

Wall mounting

The unit must only be located in dry interior locations. In order to function fault-
lessly, the device must be protected from strong electromagnetic fields in the se-
lected mounting location.
Please pay attention to separate routing
of bus cables and mains cables.
Î Choose a mounting location.
Î Drill 2 holes (Ø 6 mm, centres 113 mm) and insert the wall plugs.
Î Fasten the base part of the housing by means of the enclosed screws
(4 x 40 mm )