10-571 Installation manual internal video unit
Removing again:
Push the key which was delivered with the product into the opening to disengage the device from the
mounting plate.
3
4. PROGRAMMING AND CHANGING SETTINGS
To assign the device to a bell push button as the 1st or 2nd device, see the user manual of the power
supply 10-80x or the user manual of the service device 10-870.
To add the device to an installation as the 3rd or 4th device on a bell push button, program it in parallel
(as SLAVE) with another internal unit (see section on programming with service device below).
Programming the function key
Connect the service device to the installation via the conductors a, b and P or via
the connector provided on the external unit. To program the internal video unit,
the programming must be activated one initial time. The serial numbers of the
internal and external units can be found on the devices and can be affixed to the
installation diagram for easier programming.
Activate programming
Call diversion
"Ring-and-come-in" function
Make an internal call
Transmit control function 8
Light-switch function (standard) 94 # serial no. internal unit # 0 #
Connect the internal unit as
SLAVE to a MASTER
Switch off SLAVE programming
Please note: Only one of the functions above can be carried out.
EN
2
with the service device 10-870
95 # serial no. internal unit #
90 # serial no. internal unit # serial no. internal unit for diversion #
91 # serial no. internal unit #
92 # serial no. internal unit # serial no. internal unit # to be
called
93 # serial no. internal unit #
99 # serial no. internal unit # serial no. MASTER #
99 # serial no. internal unit # 0 #
Example of a serial number
29