Manual Reset/Restart; Shut-Down - MW TOOLS WD70 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Model WD170:
When complete "start-up" above, the left display window shows "--", the right display window shows ambient temperature
value.
Push the power switch to ON.
The default temperature setting is 20 °C, be showed on the left display window.
If the ambient temperature is lower than default temperature, the electrodes start sparking, after 7 seconds, the heater starts.
If the ambient temperature is higher than default temperature, turn thermostat control knob to desired temperature, the electrodes
start sparking, after 7 seconds, the heater starts.
Cold start up:
At low temperature keep the air vent hole (figure 6) closed by a finger during ignition to make start-up easier.
Abnormal operation:
In case of malfunction (flame failure, reduced air flow, bad combustion, etc.) the heater stops and the indicator light starts
flashing (the lock-out mode code will be showed on the display window).

5.2 Manual reset/restart

If the heater is in lock-out mode, check and remove the cause of lock-out before restarting the heater.
To reset, turn the ON/OFF switch to 0 and then again to I. In case of repeated malfunction, call technical service. Turning the
thermostat control knob will not reset the heater.

5.3 Shut-down

Move switch to OFF (0) position. Unplug the unit when not used for a long time.
WARNING!
Never disconnect the heater from mains to stop it while in operation. Always allow the cooling
sequence to be completed (WD170), otherwise the residual heat could damage internal
components.
Do not cover the heater. Do not block the air inlet and outlet.
The heater outlet is very hot during operation and after use. Do not touch! Use personal
protecting equipment if needed.
Children should be supervised to ensure that they do not play with the appliance.
The appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge.
Unplug the heater before moving it. Never pull the cable to unplug or move the unit.
Do not leave the heater unattended when in use.
Never use the appliance with wet hands or when either the heater or the power cable is wet.
If the supply cable is damaged, it must be replaced by the manufacturer, by a service agent or
a similar qualified person.
M1.1.WD70-WD100-WD170.NLFREN - 25042019