Model WD170:
When complete "start-up" above, the left display window shows "--", the right display window shows ambient temperature
value.
Push the power switch to ON.
The default temperature setting is 20 °C, be showed on the left display window.
If the ambient temperature is lower than default temperature, the electrodes start sparking, after 7 seconds, the heater starts.
If the ambient temperature is higher than default temperature, turn thermostat control knob to desired temperature, the electrodes
start sparking, after 7 seconds, the heater starts.
Cold start up:
At low temperature keep the air vent hole (figure 6) closed by a finger during ignition to make start-up easier.
Abnormal operation:
In case of malfunction (flame failure, reduced air flow, bad combustion, etc.) the heater stops and the indicator light starts
flashing (the lock-out mode code will be showed on the display window).
5.2 Manual reset/restart
If the heater is in lock-out mode, check and remove the cause of lock-out before restarting the heater.
To reset, turn the ON/OFF switch to 0 and then again to I. In case of repeated malfunction, call technical service. Turning the
thermostat control knob will not reset the heater.
5.3 Shut-down
Move switch to OFF (0) position. Unplug the unit when not used for a long time.
WARNING!
•
Never disconnect the heater from mains to stop it while in operation. Always allow the cooling
sequence to be completed (WD170), otherwise the residual heat could damage internal
components.
•
Do not cover the heater. Do not block the air inlet and outlet.
•
The heater outlet is very hot during operation and after use. Do not touch! Use personal
protecting equipment if needed.
•
Children should be supervised to ensure that they do not play with the appliance.
•
The appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge.
•
Unplug the heater before moving it. Never pull the cable to unplug or move the unit.
•
Do not leave the heater unattended when in use.
•
Never use the appliance with wet hands or when either the heater or the power cable is wet.
•
If the supply cable is damaged, it must be replaced by the manufacturer, by a service agent or
a similar qualified person.
M1.1.WD70-WD100-WD170.NLFREN - 25042019
22
EN