Wick Replacement
The EP9 500 / EP9R 500 use the 1043 Super Wick. Always use the original Essick
brand wick to maintain your unit and maintain your warranty.
1)
First, remove any items on top of the pedestal and remove the natural stone tile
and place in a safe location.
2)
Lift chassis up off the base to reveal the wick, wick retainer and float.
3)
Remove the wick and retainer assembly. Separate the two-part wick retainer.
4)
Remove the old wick, drain excess water and discard.
5)
Place new Essick 1043 wick into smaller side of the wick retainer and snap the
larger, back section into place.
6)
Then place the assembly into the base, aligning it with the built-in guides.