Problem
Water is not circulating
Pump not running
Suction is weak
/
Pump will not prime
Water in the hot tubs smells
when you open the cover.
Pressure raises rapidly
during filtration
Pressure is fluctuating
Connections are leaking
COMMON PROBLEMS
Filter is clogged
No power
Pump jammed
Valve closed
Suction pipe is clogged
Prefilter is clogged. (The basket
might seem empty while running,
since the particles are sucked to
the pump inlet)
Suction air leak.
No water in the pump.
The odor comes from the particles
in the filter mass.
Water is cloudy. pH value is too
Pump gets air.
Too loose tightening or
overtightening.
Not enough thread tape.
Miss seated o-ring.
Dirt on a O-ring.
Manual: Mass filter MF-250
Cause
high.
02.12.2020
Solution
Do backwash and rinse for the filter.
It is good to make the backwash 2-3
times every month.
Check that all electrical switches are on.
Ensure the circuit breakers are properly
set. Check the RCD.
With power switched off and power
cord disconnected.
Turn pump shaft (should spin freely).
Check all valves and open.
Clean all pipes.
Clean prefilter.
Check for leaks in the suction piping and
that there is enough water in the pool.
Make sure the filter tank is full of water.
Let the hot tub breathe without the
cover for 30 minutes. Do backwash and
rinse for the filter.
If backwash has been neglected you
might need to change the filter media.
Lower the pH value.
Check for leaks in the suction piping and
that there is enough water in the pool.
Depending on the connection type.
Open, check, clean tighten the
connection.
Do not overtighten plastic threads can
be broken easily.