6. EVIDENCE OF CONFORMITY
We declare, under our responsibility, that the prod-
ucts in this manual comply with the following
directives and standards:
- Directive EMC 2004/108/EC (Electromagnetic
compatibility)
· Standard EN 61000-6-1 y EN 61000-6-3
- Directive 2006/95/EC (Low voltage)
· Standard EN 60730-1
7. POSSIBLE FAULTS, CAUSES AND SOLUTIONS
1) The assembly does not shut down.
2) The motor operates but provides no flow.
3) The pressure is not sufficient.
4) The assembly is constantly stopping and starting.
5) The assembly does not start.
1 2 3 4 5 POSSIBLE PROBLEM
X
Closed gate valve
X
X
Tap or cistern leak
X
No water
X
Pump blocked
X
Total head height
X
X X
Air entering suction channel
X
No power
X
X
Leak in discharge pipework
The static head is greater than the
X
assembly start pressure
8. TECHNICAL DATA
Liquid temperature: ..................................... 4ºC - 60ºC
Ambient temperature: ................................. 0ºC - 40ºC
Storage temperature: .............................. -10ºC - 50ºC
Ambient relative humidity, max.: .......................95%
Start up pressure: ....................................... 1.5 - 2.5 bar.
(See serial number on the nameplate and fig. 4)
Eduard Rodriguez (Director)
SOLUTIONS
Open valve
Repair leak
Wait till water level recovered and press red button
Call service engineer
Chk. geometric ht. plus loss of head
Carefully seal all joints and connectors
Check fuses
repair leak
Chk. start-up setting is correct
7
EN
MEBA S.L.U.
Girona - Spain