SPECIFICATIONS
Electrical
Installation must comply with all applicable electrical codes
and be properly grounded (earthed).
For wall hoods, locate the electrical supply within the
shaded area shown in the illustration below. Allow a
minimum 305 mm electrical cable for connection. For island
hoods, locate the electrical supply on the ceiling inside the
top of the hood. Allow a minimum 1.8 m electrical cable for
connection. A separate circuit, servicing only this appliance
is required.
ELECTRICAL REQUIREMENTS
Electrical Supply
220-240V, 50Hz
220V, 60Hz
Service
Connection of this appliance should be
IMPORTANT NOTE:
through a fused connection unit or a suitable isolator, which
complies with national and local safety regulations. The
on/off switch should be easily accessible after the appli-
ance has been installed. If the switch is not accessible after
installation (depending on country) an additional means of
disconnection must be provided for all poles of the power
supply. When switched off there must be an all pole contact
gap of 3 mm in the isolator switch. This 3 mm contact dis-
connect gap must apply to any isolator switch, fuses and/or
relays according to EN60335.
E
457
mm
762 mm TO 914 mm BOTTOM EDGE TO COUNTERTOP
Electrical location—all wall hoods.
Ducting
WARNING
To reduce the risk of fire, use only metal ducting.
The air must not be discharged into a flue that is used for
exhausting fumes from appliances burning gas or other
fuels.
IMPORTANT NOTE:
Consult a qualified HVAC professional
for specific installation and ducting applications.
Cooktop ventilation hoods accommodate a 152 mm round
duct. Use only rigid metal ducting.
A straight, short duct run is most effective and will ensure
proper performance. If the duct run exceeds 15 m, a higher
1.9A
CMH blower may be required to maintain proper air flow. A
remote blower installed on a short duct run may increase
the potential for noise.
Internal blowers require a roof or wall cap. Connect ducting
to the cap and work back towards the hood. Use sheet
metal screws and aluminum tape or high temperature duct
tape to seal joints between ducting sections.
Cooktop hoods include a backdraft damper. Local codes
may require the use of an additional backdraft and/or
make-up air damper. Contact your local HVAC professional
for specific requirements.
A make-up air damper is available through an authorized
Wolf dealer.
INSTALLATION
Installation
WALL HOOD
If an internal blower will be used, install the blower prior
to mounting the hood. Refer to page 4 for internal blower
installation.
Mark the center line for location of two mounting holes
1
using dimensions shown in the chart and illustration
below. Additional wall framing is recommended in this
location. If wall framing is not available, the use of wall
anchors is recommended. Install the mounting screws
so there is approximately 6 mm gap between the screw
head and wall. Position the two mounting brackets for
the chimney flue, then install using two mounting screws
per bracket (screws must be a minimum length of 51
mm). Refer to the illustration below.
MOUNTING LOCATION
Black Hood
Stainless Hood
Glass Hood
CEILING
19
mm
433
mm
232
mm
A
BOTTOM OF HOOD
Mounting location.
Place the mounting tabs over the mounting screws. Use
2
the leveling adjustment screws to ensure the hood is
level. Refer to the illustration below.
Mount the electrical plate to the wall using screws
3
provided.
Place the backdraft damper on the round discharge then
4
install 152 mm round metal ducting (not provided) to the
damper and seal with aluminum tape.
Make wiring connections. Refer to pages 4–5.
5
Once wiring connections are complete, secure the upper
6
chimney flue to the mounting brackets using screws
provided (screws must be a minimum length of 7 mm
and maximum length of 14 mm). Refer to the illustration
below. Place the lower chimney flue over the upper, then
lower until it rests on the hood.
A
324 mm
WARNING
416 mm
Failure to install the screws or fixing device in accor-
319 mm
dance with these instructions may result in electrical
hazards.
LEVELING
SCREW
MOUNTING
TAB
Mount and level hood.
Install telescopic flue.
wolfappliance.com
|
3