Table Des Matières; Securing The Seal; Secure The Seal On The Flat Duct Elbow At A Max; Imum Of 5 Mm From The Edge - NEFF T47PD7BX2 Notice D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 24
If required, also use screws to secure it.
2.
33
Installing the appliance for air recirculation mode
with circulating-air duct
For circulating-air mode, use the seal, the circulat-
1.
ing-air duct, the diffuser and the odour filter.
Observe the dimensions for the different flat duct
2.
bends. → Page 19
34
Inserting the flat duct elbow
Insert the flat duct elbow into the outlet opening
on the rear of the appliance.
→ Fig.
35
Inserting the appliance into the worktop cut-out
Ensure that the connection cable is connected to
1.
the appliance.
Carefully insert the appliance into the worktop cut-
2.
out.
36
Establishing the pipework between the
appliance and the diffuser
Connect the components of the circulating-air duct
1.
to each other.
37
Connect the circulating-air duct to the flat duct el-
2.
bow on the rear of the hob.
38
Connect the diffuser to the circulating-air duct.
3.
39
Install the appliance for air extraction mode
For air extraction mode, use the seal and the
1.
acoustics filters.
Observe the instructions for the exhaust air pipe.
2.
→ Page 21

Securing the seal

Secure the seal on the flat duct elbow at a max-

imum of 5 mm from the edge.

→ Fig.
34
Establishing the piping
Insert the flat duct elbow into the outlet opening
1.
on the rear of the appliance.
→ Fig.
35
If required, install additional piping elements.
2.
Inserting the appliance into the worktop cut-out
Ensure that the connection cable is connected to
1.
the appliance.
Carefully insert the appliance into the worktop cut-
2.
out.
→ Fig.
36
Connecting the exhaust air pipe
Secure the exhaust air pipe to the flat duct bend.
1.
Establish the connection to the exhaust air open-
2.
ing.
Seal the joints appropriately.
3.
Inserting filters
Note: For circulating-air mode, insert the odour fil-
ters.
For air extraction mode, insert the acoustics filters.
Observe the filters' air flow direction.
1.
Insert two of the filters into the left and right of the
2.
appliance, and slide them forwards.
40
Insert the other filters into the left and right of the
3.
appliance.
41
Inserting grease filters
Insert the grease filter.
42
Establishing the connection to the power
supply
Observe the connection data on the rating plate.
1.
For 3 N, connect the cable to the mains socket in
2.
accordance with the figure.
→ Fig.
43
For 2 N, connect the cable to the mains socket in
3.
accordance with the figure.
→ Fig.
44
For 1 N, connect the cable to the mains socket in
4.
accordance with the figure.
→ Fig.
45
For 2 L/2 N, connect the cable to the mains
5.
socket in accordance with the figure.
→ Fig.
46
Note the colours of the cables.
6.
- BN: Brown
- BU: Blue
- GN/YE: Yellow and green
- BK: Black
- GY: Grey
If required, arrange the supplied wire end ferrules
7.
differently depending on the type of connection.
To connect two cables, if required, use a wire end
8.
ferrule.
Shorten the wires.
-
Remove the insulation.
-
Checking the function
Switch on the appliance.
1.
If
,
or
lights up, the appliance is not
2.
connected correctly.
→ "Checking and correcting the electrical connec-
tion", Page 23
If no faults appear in the appliance's display, use
3.
the operating instructions to check that the ventila-
tion is working.
Checking and correcting the electrical connection
Disconnect the appliance from the power supply.
1.
Check whether the connection to the appliance
2.
(fig. 4) and the building-side connection (fig. 8)
correspond to the connection diagram in these in-
stallation instructions.
→ "Preparing the electrical connection", Page 21
→ "Establishing the connection to the power sup-
ply", Page 23
For 3 N, observe the following figure.
3.
→ Fig.
47
For 2 N, observe the following figure.
4.
→ Fig.
48
For 1 N, observe the following figure.
5.
→ Fig.
49
Sealing crevices
Requirement: You must carry out a function test be-
fore sealing the joint.
Seal the gap around it using suitable, heat-resist-
1.
ant silicone, e.g. Novasil® S70 or Ottoseal® S70.
→ Fig.
50
Unsuitable silicone adhesive causes permanent
discoloration to natural stone worktops.
23

Publicité

Table des Matières
loading

Table des Matières