The power supply to the appliance must be protected by a dedicated 30 mA Residual Current Device (RCD),
complying with the standards and regulations in force in the country in which it is installed.
Do not use any extension lead when connecting the appliance; connect the appliance directly to a suitable power
supply.
Before carrying out any operations, check that:
 The voltage indicated on the appliance information plate corresponds to the mains voltage.
 The power grid must be adapted to the power requirements of the appliance, and is grounded.
 The plug (where applicable) is suitable for the socket.
Do not disconnect and reconnect the appliance to the power supply when in operation.
Do not pull on the power cord to disconnect it from the power supply.
If the power cord is damaged, it must be replaced by the manufacturer, its technician or a qualified person to
guarantee safety.
Do not perform maintenance or servicing operations on the appliance with wet hands or if the appliance is wet.
Before connecting the appliance to the power supply, check that the connection unit or socket to which the
appliance will be connected is in good condition and shows no signs of damage or rust.
In stormy weather, disconnect the appliance from the power supply to prevent it from suffering lightning damage.
Do not immerse the appliance in water or mud.
WARNINGS CONCERNING APPLIANCES CONTAINING REFRIGERANT R32
R32 refrigerant is classed under category A2L as mildly flammable.
Do not release R32 fluid into the atmosphere. These are fluorinated greenhouse gases, covered by the Kyoto
Protocol, with a Global Warming Potential (GWP) of 675 (European regulation EU 517/2014).
The appliance must be stored in a well-ventilated location away from all ignition sources.
Install the unit outdoors. Do not install the unit indoors or in an enclosed and non-ventilated outdoor location.
Do not use means for accelerating the defrosting or cleaning process other than those recommended by the
manufacturer.
The appliance must be stored in a room without any permanent ignition source (such as open flames, operating
gas appliance or operating electric heating).
Do not perforate or incinerate.
Please note that R32 refrigerant may give off a certain odour.
In order to comply with the applicable standards and regulations in terms of the environment and installation, in
particular French decree No. 2015-1790 and/or European regulation EU 517/2014, a leak test must be performed
on the cooling circuit at least once a year. This operation must be carried out by a specialist certified to test
cooling appliances.
Please keep the display controller in a dry area, or well close the insulation cover to protect the display controller
from being damaged by humidity.
MAINTENANCE: WARNINGS CONCERNING APPLIANCES CONTAINING R32 REFRIGERANT
When servicing the appliance, the composition and state of the heat transfer fluid must be checked, as well as the
absence of any traces of refrigerant.
During the annual appliance sealing test in accordance with applicable legislation, the high and low pressure
switches must be checked to ensure that they are securely fastened to the refrigerant circuit and that they cut off
the electrical circuit when tripped.
During maintenance work, ensure there are no traces of corrosion or oil around the cooling components.
Do not braze or weld the pipe if there is refrigerant inside machine. Please do not charge the gas when in a
confined space.