Télécharger Imprimer la page

Faber TENDER Instructions D'installation page 6

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION DIMENSIONS
The Tender chimneys are adjustable and designed to meet varying ceiling
heights as indicated in FIGURE 4. The chimneys can be adjusted for ceil-
ings between 7' 9 2/16" and 9' 11 2/16" depending on the distance between
the bottom of the hood and the cooktop (distance x in FIGURE 4).
upper
1" min
chimney
21 10/16
max
"
22 1/16"
lower
chimney
9
canopy
7/16"
x = distance from hood to cooktop
x
(varies depending on installation)
min - 24", suggested max - 30"
also consult cooktop
manufacturer's recommendation
36"
cabinet base
FIGURE 5
min & max ceiling height examples
x = 24"
x = 26"
min
min
7'
7'
9 2/16"
11 2/16"
max
max
9'
9'
5 2/16"
7 2/16"
19
"
1. Disconnect and move freestanding range from cabinet
opening to provide easier access to upper cabinet and rear
wall. Put a thick, protective covering over cooktop, set-in
range or countertop to protect from damage or dirt.
2. Determine and clearly mark with a pencil the center line
on the wall where the rangehood will be installed.
3. The canopy attaches to the wall by two mounting brackets
(1 in FIGURE 5). The canopy of the rangehood hangs on
x = 28"
x = 30"
the two brackets which must be mounted with the flanges
min
min
on the top of the bracket and pointing away from the wall.
8'
8'
1 2/16"
3 2/16
Before installing the brackets, the adjustment screws must
max
max
be installed into the bottom of the bracket. These two
9'
9'
9 2/16"
11 2/16"
screws are provided in the hardware package and have
hexagon heads with a slot for a flat blade screwdriver.
The dimensions illustrate mounting the canopy 24" above
For shorter ceilings,
the cooking surface.
have the chimney
cover(s) cut at a sheet
metal shop. For higher
If a Backsplash is to be used with this rangehood, it must
ceiling installations, the
be installed before the rangehood. Installation instructions
High Ceiling Chimney
for the Backsplash are supplied in its box. The height
Kit includes a new 39"
of the Backsplash will determine the bottom edge of
upper chimney which
the canopy.
would replace the 21
10/16" upper chimney
4. The chimney mounts by two brackets (2 in FIGURE 5).
that came with the
Note the position of the brackets. The top bracket should
hood.
be installed about 1/8" away from the ceiling. The bottom
bracket must be installed at the bottom point of the upper
chimney sleeve.
Determine the proper location for each bracket and install
FIGURE 4
the brackets on the wall. MAKE SURE THAT THE BRACK-
ETS ARE SECURELY FASTENED TO THE WALL.
5. Determine and make all necessary cuts in the wall for the
ductwork. Install the ductwork before the rangehood.
6. Determine the proper location for the Power Supply
Cable (FIGURE 6). Use a 1 1/4" Drill Bit to make this
hole. Run the Power Supply Cable. Use caulking to seal
around the hole. DO NOT turn on the power until instal-
lation is complete.
PREPARE THE WALL
30 MODELS
36 MODELS
FIGURE 6
Version 07/11- Page 6

Publicité

loading

Ce manuel est également adapté pour:

Tend30ss300Tend36ss300Tend30ssTend36ss