Warranty; Operator Responsibilities; Technical Data - BWT PERMAQ mobile Notice De Montage Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2.4 Warranty

If the product malfunctions during the warranty period, contact your contract
partner, the installation company, and quote the unit type and production
number (see Technical specifcations or the type plate on the unit).

2.6 Technical data

BWT PERMAQ
®
Nominal capacity *)
Feedwater pressure (min./max.)
Feed water connection
Concentrate connection
Permeate connection
Salt level, total dissolved solids (TDS)
Salt retention rate
Permeate output WCF (min./max.)
Feedwater temperature (min./max.)
Ambient temperature (min./max.)
Silt density index (SDI) max.
Silicate (SiO
) max.
2
Iron and manganese (Fe+Mn)
Protection class
Oxydants
Electric power consumption
Electrical connection / fuse protection
Dimensions: Width, depth, height (W x D x H)
Operating weight
Production- and reference no.
*) Feedwater quality of 15°C, TDS ≤ 1'000mg/l, SDI ≤ 3.0 %/min, SiO2 ≤ 15mg/l,
oxydants ≤ 0.05mg/l

2.5 Operator responsibilities

You have purchased a product that is durable and easy to service.
However, all technical equipment requires regular servicing in order to gua-
rantee optimal functionality.
Regular checks by the operator are required for the warranty and proper
functioning of the unit.
Visual inspection for tightness
Check filter and differential pressure
Check pressure switch
Check solenoid valve
Another precondition for functioning and warranty is the exchange of wearing
parts in the specified maintenance intervals. Perform a maintainace at least
once per year.
Check the connecting line and housing for damage whenever doing any
maintenance work
Exchange of wearing parts
Membrane element
Pressure pipe caps
Sealings
Pressure pipe
According to BGV A2 (VBG4) electrical safety check every 4 years
Wearing parts may only be replaced by qualifed personnel (ftters or after-
sales service team).
We recommend that you enter into a maintenance agreement with your fitter
or the after-sales service team.
Type
mobile 350
l/h
340 – 370
bar
2.0 / 6.0
DN
20
DN
15
DN
20
mg/l
1000
%
> 95.0
%
35 / 40
°C
5 / 25
°C
5 / 40
< 3
%/min
mg/l
15
mg/l
< 0.05
IP 54
mg/l
< 0.05
kW
0.55
V/Hz/A
230/50; 10
mm
600 x 750 x 1250
kg
67
6-470804
every 3 months
every 6 months
every 3 years
every 6 years
every 6 years
every 10 years
BWT PERMAQ
mobile 350
®
W
D
EN
weekly
weekly
15

Publicité

Table des Matières
loading

Table des Matières