Unscrew the filter container of the 5µm filter (5).
Place the filter insert and screw on the filter container in a
finger-tight manner.
5
17
15
Connect the hose from the permeate outlet (17) to the system to be filled.
Connect mains plug.
Activate master switch.
Open the ball valves of the raw water inlet (14) and the permeate
outlet (15). The unit is activated and the permeate production starts.
19
13
20
Setting of system pressure and pressure reducer
Open black twist handle (20).
Deactivate master switch.
Open outlet ball valve (15) for pressure relief.
Unscrew the setting bolt (13) at the pressure reducer until approx. 5 threads
are visible.
19
Close ball valve at the permeate outlet (15).
Turn the setting screw clockwise until the pressure gauge (19) shows desired
deactivation pressure (system pressure).
Note: An additional, firmly set pressure switch does not permit a pressure
above 4.5bar.
13
EN
13