R A D I A N T
O U T D O O R
H E A T E R S
Installation Requirements
®.
The ideal mounting position for the HEATSTRIP
Design is on the ceiling, directly above the area to be heated. If this is
®.
not possible, HEATSTRIP
can be mounted on a wall and angled downwards. In this situation, ensure the mounting
height is in the range of 2.1m to 2.7m and the table is within 2.5m of the wall.
For mounting heights more than 3m, we recommend the use of the optional accessories to reduce the height of the heater
®.
to 2.3m - 2.7 m. This will increase the effectiveness of your HEATSTRIP
Refer to the Mounting Accessory section for
more information.
Electrical connections/GPO's should not be located at the back of the heater. They should be located outside the physical
footprint of the units to minimize heat build-up behind the units.
If the heater is to be mounted on an incline (eg. Vaulted ceiling), ensure the electrical connection is located at the lowest
point of the heater.
Incorrect Installation
Correct Installation
CEILING
The heating surface must never be directed toward the ceiling
10