3.2.2 To prepare drain work

Make sure that condensation water can be evacuated properly.
NOTICE
If the drain holes of the outdoor unit are blocked up, provide
space of at least 300 mm below the outdoor unit.
An additional drain pan kit (EKDP008CA) can be used to gather the
drain water. The drain pan kit consists of:
a Drain pan
b U-beams
ERLQ004~008CAV3
Daikin Altherma low temperature Split outdoor unit
4PW73435-1 – 2012.05
a
b

3.2.3 To install the outdoor unit

CAUTION
Do NOT remove the protective cardboard before the unit is
installed properly.
1
Lift the outdoor unit as described in To remove the accessories
from the outdoor unit.
2
Install the outdoor unit as follows:
a
1
a Air outlet
NOTICE
The pedestal MUST be aligned with the backside of the U-
beam.
3
Remove the protective cardboard and instruction sheet.
b
a
a Protective cardboard
b Instruction sheet
3 Installation
a
2
2x
Installation manual
3