DANGER
Risk of death!
Risk of electric shock.
Maintenance work on electrical components may only be carried out by a qualified
electrician.
11.2. General information
⇒ The pugmill is practically maintenance-free.
⇒ The drive motor is a closed system that has no lubrication points for maintenance of the machine.
⇒ In the case of the drive motor, however, the gear oil must be changed every 4,000 operating hours or 4
years, whichever comes first (see next section). During use, make a note of the operating hours or the
operating time of the machine in order to be able to comply with these intervals.
11.3. Maintenance intervals
11.3.1. Mechanical components
Carry out the maintenance and tests at the intervals listed below. Replace defective components immediately.
Action
Visual inspection of the safety
ring
Clean the pugmill
Visual inspection of the housing
Visual inspection of the mixing
shaft with wing blades
Visual inspection of the nozzle
Visual inspection of the worktable
Visual inspection of the cutting
device
Visual inspection of the controls
Visual inspection of the power
cord and power plug
Visual inspection of the screw
connections on the outside of the
housing
Changing the oil in the drive
motor
X
X
46 / 191 - EN -
X
X
X
X
X
X
X
X
X