20
2000mA for larger gauges. This ensures that you still have some
reserve left.
-
standing locomotives - not illuminated 2.5mA, illuminated approx.
50mA for each bulb.
-
illuminated wagons - each bulb approx. 50mA.
If the calculated sum exceeds the maximum current available from the
Digital plus by Lenz
this is the case, divide the layout into several supply areas. Use an
amplifier LV102 for supplying each of these areas.
5
The connections
Power
supply U,V
Track
connection J,K
5.1 Power supply: terminals U,V
The LV102 is connected to the transformer via two cables at the
terminals U and V. We recommend the transformer TR150 for
operation with the LV102.
5.2 Track connection: terminals J,K
Only use cables with sufficiently large cross-sections to connect the
tracks and then twist this cable (we recommend 0.25 mm
extended routes you need additional points of current supply at
regular intervals.
®
system used, you will need more amplifiers. If
U V J K
ground
Fig. 1: The connections of the LV102
Information LV102
connection for
amplifiers
C D E
C,D,E
2