Standards, regulations and directives

Observe all national, state, and local code, regulations
and standards applicable to installation and operation of
the tank!
All electrical components must be approved for the USA
and Canada.
4

Moving the tank

WARNING: Risk of injury from carrying heavy loads and
inadequately securing loads for transport!
▶ Use suitable means of transportation, e.g. a dolly
with strap.
▶ Secure the load against falling.
Where possible, do not remove the tank from its
packaging until it has reached the installation location.
This ensures protection during handling.
▶ Position the dolly at the back of the packed tank.
▶ Secure the tank to the means of transportation with a strap.
▶ Transport the tank to the installation location.
▶ Only remove the tank from the packaging at the installation location.
Fig. 5
Transporting with a dolly
S32/5 – 6 720 819 302 (2017/11)
5
The tank is delivered fully assembled.
▶ Check that the tank is complete and undamaged.
5.1
5.1.1
▶ Place the DHW tank on a plinth if there is any danger of water
collecting on the floor of the setup site.
▶ The installation site must be a dry and frost-free room.
▶ Observe the minimum room height ( Tab. 6, page 8) in the
installation room. No minimum wall clearance required.
▶ Maintain a distance of 2" (51 mm) from heated pipes and
combustible surfaces.
5.1.2
▶ Unpack the tank by removing the wrap, wooden boards and foam pad
on the top.
6 720 800 035-03.1ITL
Standards, regulations and directives

Installation

Tank installation

Requirements for installation location

NOTICE: Risk of damage from inadequate load-bearing
capacity of the supporting substructure or unsuitable
floor surface!
▶ Ensure that the installation area is level and offers
sufficient load-bearing capacity.
NOTICE: Risk of damage from stress cracking and
corrosion!
▶ Position the tank in a dry room free from the risk of
freezing.
▶ Install the tank only in closed-loop, unvented
hydronic heating systems.
▶ Open expansion vessels may NOT be used with this
tank.
NOTICE: Install an adequate drain pan if required by
code, or if a leak could result in property damage. Follow
drain pan manufacturer's instructions.
A minimum 19" (480 mm) clearance is required above
the DHW tank in order to remove the magnesium
anodes.

Positioning the tank

3
9