Télécharger Imprimer la page

Publicité

Liens rapides

RLP - Radiolink Plus™
‫ﺗﻌﻠﻳﻣﺎﺕ ﺍﻟﺗﺷﻐﻳﻝ‬
THIS MANUAL WAS WRITTEN IN THE ENGLISH LANGUAGE AND PROFESSIONALLY
Part No:
TRANSLATED TO ALL OTHER LANGUAGES CONTAINED WITHIN THIS DOCUMENT.
SU6043
PLEASE NOTE THAT STRAIGHTPOINT ACCEPT NO RESPONSIBILITY FOR ANY ERRORS OR
OMISSIONS.

Publicité

loading

Sommaire des Matières pour Crosby RLP Radiolink Plus

  • Page 1 RLP - Radiolink Plus™ ‫ﺗﻌﻠﻳﻣﺎﺕ ﺍﻟﺗﺷﻐﻳﻝ‬ THIS MANUAL WAS WRITTEN IN THE ENGLISH LANGUAGE AND PROFESSIONALLY Part No: TRANSLATED TO ALL OTHER LANGUAGES CONTAINED WITHIN THIS DOCUMENT. SU6043 PLEASE NOTE THAT STRAIGHTPOINT ACCEPT NO RESPONSIBILITY FOR ANY ERRORS OR OMISSIONS.
  • Page 2 01-04 General description and warnings RLP fitting batteries RLP wireless signal 07-08 RLP using a load cell 09-10 Product aftercare Service and calibration Warranty Notes Part No: SU6043...
  • Page 3 All products manufactured and sold by Straightpoint Ltd, are sold with the express understanding that the purchaser and user are thoroughly familiar with the safe use, proper care and application of the product. Responsibility for the safe use, proper care and application of the product rests with the user. Failure of the product can occur due to misapplication, abuse, overloading, or improper care and maintenance.
  • Page 4 Todos los productos que fabrica y vende Straightpoint Ltd se venden sabiendo explícitamente que el comprador y el usuario son plenamente conocedores de utilizar el producto de forma segura, cuidarlo y emplearlo. El usuario es responsable de utilizarlo de forma segura, cuidarlo y emplearlo. El mal funcionamiento del producto puede deberse a un uso indebido, abuso, sobrecarga, o cuidado y mantenimiento inadecuados.
  • Page 5 Straightpoint Ltd Straightpoint Ltd : ASME B30.26-2010 « ». Straightpoint Ltd, Straightpoint Ltd Straightpoint Ltd. Straightpoint Ltd Straightpoint Ltd Όλα τα προϊόντα που κατασκευάζονται και πωλούνται από τι Straightpoint Ltd, πωλούνται ε τη ρητή επιφύλαξη ότι ο αγοραστή και ο χρήστη είναι πλήρω εξοικειω ένοι ε την ασφαλή χρήση, την κατάλληλη φροντίδα και την εφαρ ογή του προϊόντο . Η...
  • Page 6 Alla produkter som tillverkas och säljs av Straightpoint Ltd säljs med uttryckliga hänvisningar om att köparen och användaren har god kännedom om säker användning, skötsel och tillämpningen av produkten. För säker användning, skötsel och tillämpningen av produkten ansvarar användaren. Felaktig användning, missbruk, överbelastning eller felaktig skötsel och underhåll kan leda till att produkten fördärvas. Det finns många statliga standarder och branschstandarder som omfattar produkterna som tillverkas och säljs av Straightpoint Ltd .
  • Page 7 Advertencia: asegúrese de que las baterías estén instaladas correctamente y de que la polaridad sea correcta. Nota: Crosby | Straightpoint recomienda el uso de pilas alcalinas Duracell LR6. Rimuovere il coperchio posteriore del Radiolink utilizzando un cacciavite a lama piatta. Inserire le batterie e rimettere il coperchio.
  • Page 8 Back Front 300m/984ft 1000m/3280ft Direction of radio emissions Part No: SU6043...
  • Page 9 Le WLL est marqué sur le côté de chaque Radiolink, par exemple Max : 6,5 tonnes x 0,001te. Avant d'utiliser le Radiolink assurez-vous que la capacité du dynamomètre est adaptée à la tâche en cours. Pour chaque numéro de pièce RLP , utilisez les manilles compatibles Crosby et les broches de chargement Ø...
  • Page 10 Avoid shock loads. Do not apply large twisting forces to these devices as it may damage them beyond repair. If using RLP with SW-HHP handheld please refer to user manual SU6034 for guidance on that product. Remove the device from the test site, clean and store, ideally in a Straightpoint carry case. If the device is to be stored for long periods of time please remove the loadcell and handheld display batteries.
  • Page 11 The Radiolink is sealed to IP67 / NEMA6 standards. The effects of solvent on the device can not be guaranteed, and should therefore be avoided. Avoid use within 20-30 minutes of rapid changes in temperature, for example moving the device from a cold vehicle into a warm room. The change in temperature can affect the accuracy of the device.
  • Page 12 IP67 / NEMA6. 20-30 +50°C ( 14 122°F). Duracell LR6. −20°C +54°C −4°F 129°F. Energizer L91 −40°C +60°C −40°F 140°F. «OVERLOAD» Οι συσκευέ αυτέ σφραγίζονται σύ φωνα ε τα πρότυπα IP67 / NEMA6. Η επίδραση διαλύτη στη συσκευή δεν είναι εγγυη ένη και θα πρέπει επο ένω να αποφεύγεται. Αποφύγετε...
  • Page 13 These products are supplied with a certificate of calibration which is valid for one year. After this date, it is recommended the device is recalibrated by Straightpoint or an approved calibration laboratory. Contact the Straightpoint service department or your supplier for more information. In the unlikely event of this device failing, fit new batteries and re-test.
  • Page 14 Straightpoint (UK) Ltd warranty this product against malfunction for a period of two years from manufacture. Conditions of warranty: 1) The equipment is used as described exactly in the operators manual supplied. 2) Whilst we make every effort to ensure each device is calibrated before despatch, Straightpoint (UK) Ltd do not accept responsibility for inaccurate readings indicated by this equipment. 3) In the event of malfunction, the device is returned to the manufacturer: Straightpoint (UK) Ltd, Unit 9 Dakota Park, Havant, Hampshire, UK, PO9 2NJ.
  • Page 15 Part No: SU6043...
  • Page 16 Crosby | Straightpoint Unit 9, Dakota Park, Downley Road, Havant, Hampshire, PO9 2NJ UK · Tel: +44 (0)2392 484491 2801 Dawson Road, Tulsa, OK 74110 · USA · Tel: +1 (918) 834-4611...