Honeywell Home RedLINK Guide D'installation page 10

Système sans fil avec module d'interface. commande sans fil pour thermopompes
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

RedLINK
Installation Guide (EIM)
TM
Installer setup tables
Setup function
15
Compressor off time
(minimum)
16
Schedule format
17
External fossil fuel
kit
18
Dual fuel heat pump
control
20
Droop temperature
(dual fuel)
21
Dual fuel upstage to
furnace timer
22
Outdoor air sensor? 0
24
Heat pump
compressor lockout
(balance point)
25
Heat pump
auxiliary lockout
26
Auxiliary heat con-
trol
27
Maximum heat
setpoint
28
Minimum cool
setpoint
32
Temp. display offset
(indoor)
33
Temp. display offset
(outdoor)
35
Humidity display
offset (outdoor)
69-2091EFS—09
Settings & options (factory default in bold)
5
5 minutes (Heat On/Cool On flashes during off time)
[Options: 0 to 4 minutes]
Applies only to Model TH6320
0
Weekday/weekend program schedule
1
Weekday/Saturday/Sunday program schedule
1
External fossil fuel kit controls backup heat
0
Thermostat controls backup heat (outdoor sensor required)
1
Droop
control**
0
No droop
control**
2
Droop control with Aux Heat
2
Auto temperature droop 2° F (1° C)
[Options: 2 to 5 (2 to 5° F / 1 to 2.5° C)]
1
1
hour**
[Options: 0 (off) to 16 hours]
No
1
Yes
0
No heat pump compressor
1
5° F (-15° C)
2
10° F (-12° C)
3
15° F (-9.5° C)
4
20° F (-6.5° C)
5
25° F (-4° C)
6
30° F (-1° C)
0
No heat pump auxiliary
1
5° F (-15° C)
2
10° F (-12° C)
3
15° F (-9.5° C)
4
20° F (-6.5° C)
5
25° F (-4° C)
6
30° F (-1° C)
7
35° F (1.5° C)
Applies only to Model TH5320
0
Comfort**
1
Economy
90
Max. heat temperature setting is 90° F (32° C)
[Options: 40 °F to 90 °F (4.5 °C to 32 °C)]
50
Min. cool temperature setting is 50° F (10° C)
[Options: 50 °F to 99 °F (10 °C to 37 °C)]
0
Thermostat displays actual temperature
[Options: -3 to +3 °F offset (-1.5 to +1.5 °C)]
0
Thermostat displays actual temperature
[Options: -5 to +5 °F offset (-2.5 to +2.5 °C)]
3
Thermostat displays actual humidity
[Other options: 0 = -15%, 1 = -10%, 2 = -5%, 4 = +5%, 5 = +10%,
6 = +15% offset]
Lockout**
lockout**
7
35° F (1.5° C)
8
40° F (4.5° C)
9
45° F (7° C)
10
50° F (10° C)
11
55° F (13° C)
12
60° F (15.5° C)
lockout**
8
40° F (4.5° C)
9
45° F (7° C)
10
50° F (10° C)
11
55° F (13° C)
12
60° F (15.5° C)
13
65° F (18.5° C)
10
** See page 11

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

FocusproThm5320rThm5320r1000/uYth6320r1001Th5320r1002

Table des Matières