Configuring The Remote Access; Changing The Password; Troubleshooting - Resol DL2 Plus Manuel

Masquer les pouces Voir aussi pour DL2 Plus:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

7.25 Configuring the remote access
ATTENTION!
Third-party access!
When the default remote access password is not changed, third
parties may gain unauthorised access to the controller connected.
Î Change and note down the remote access password
and keep it in a suitable place.
The remote access password is required whenever a controller connected to the
device is to be accessed via the RPT Parameterisation Tool.
In order to change the remote access password, proceed as follows:
1. In the Configuration main menu, select the Remote access submenu.
2. Enter the new password into the VBus password field.
The factory setting for the remote access password is vbus.
3. Click Save configuration.
VBus access over local network and Remote access over Internet are
activated by default.
Î In order to deactivate the VBus access over local network and/or the Re-
mote access over Internet, click the corresponding toggle button.

7.26 Changing the password

In order to change the user password of the Web interface, proceed as follows:
1. In the Configuration main menu, select the Users submenu.
2. Under Change password click the toggle button.
3. Enter the current password into the Password field.
The default password can be found on the underside of the housing (Web-
Interface).
4. Enter the new password into the New password field.
5. Enter the new password into the Confirm new password field.
6. Click Save configuration.
38
8

Troubleshooting

Problem
Solution
The user password is
When the user password is not available, the device has
not available.
to be reset to its factory settings in order to regain ac-
cess to the Web interface. The password can be found on
the underside of the housing (Web-Interface).
Signal strength of the
Î Use the device in another location.
WLAN too low.
The VBus
®
The status LED is
If all network settings are changed, it might occur that the
green although no con-
status LED is not able to signal this change.
nection is available.
Î Restart the device.
No connection to
Î If the device is connected via WLAN and LAN and if
VBus.net possible.
one of the connections is then disconnected, restart
the device.
Î Use one connection type only.
cable can be extended to up to 50 m.

Publicité

Table des Matières
loading

Table des Matières