8 ABNORMAL DISPLAY AND TROUBLE SHOOTING
Abnormal condition
No battery detected
Battery short circuit
Inverse battery connections
Voltage is too low
Voltage is too high
Battery bad cell protection
Over-temperature protection
Over
voltage
protection
Over
current
protection
Bad battery (in Test mode)
Need to charge (in Test
mode)
Possible cause
Loose connection
Incorrect connection
Incorrect connection
If the Battery voltage is less than 2-4V,
the charger will not start to recharge the
battery automatically
12V batt. set with the 24V mode
Battery has failed
The charger needs to be checked
control
The charger needs to be checked
control
The charger needs to be checked
Battery is short circuited or has failed
Deeply discharged or sulphated battery
Step 1:
Press
Step 2: Press
Step 3: Press
to Start or Stop the Testing process.
Display in Test mode:
Battery voltage: displays the vehicle's battery voltage (V)
Starting System: displays the voltage waveform and minimum voltage
Test Result: Excellent, Good, needs to be recharged, Bad
Suggested solution
Check the battery and terminal connections
Check the battery and cables connections.
Reverse the polarity of the connection to the
battery
Press and hold
the charging process to start
(Check the connections before activating this function)
Change to the correct 12/24V mode
Replace the battery
Contact your distributor
Contact your distributor
Contact your distributor
Replace the battery
Use the Charge mode to recharge the battery