TROUBLE SHOOTING
WINTERIZING
Protect the pump, the filter and the piping from freezing.
Open the drain (5) and shift the valve handle to "Back-
wash".
Remove the pump to a dry and warm room.
Do not wrap the motor with plastic covering as condensa-
tion may damage the pump.
In installations where the pump can not be drained, a
40% propylene glycol, 60% water solution will protect to
-46°C.
Do not use other anti-freeze solutions, these are all highly
toxic and will damage the pump.
ELECTRICAL CONNECTION
The electrical motor must be wired by a professional
according to the installation instructions of your local
electricity company.
AT THE INSTALLATION OF THE PUMP A MO-
TOR SECURITY HAS TO BE FORESEEN WHICH
SHOULD BE IN ACCORDANCE WITH THE NOMI-
NAL POWER OF THE MOTOR.
Monphase
5ABGA-1
P1: 0.3kW
P: 0.18kW
5ABGB-1
P1: 0.40kW
P: 0.5kW
5ABGC-1
P1: 0.59kW
P: 0.37kW
5ABGD-1
P1: 0.90kW
P: 0.55kW
The supply voltage should be within ± 5% of the design
voltage, specified on the nameplate of the motor.
Single-phase motors should be connected at the terminals
as indicated in the junction box.
CAUTION:
MAKE SURE THAT YOU INTERRUPT THE POW-
ER SUPPLY TO THE CABLES WHEN CONNECT-
ING THE CABLES OF THE PUMP
Every motor must be permanently grounded.
An earth safety or circuit breaker switch with a sensitivity
of 30mA should always be included at the installation.
The wiring size and the type of fuses (min. H05RN-F)
should be selected in accordance with the motor capacity.
ATTENTION:
CONNECTIONS WHICH ARE NOT CONFORM TO
THE ABOVE-MENTIONED SAFETY INSTRUC-
TIONS, ARE NOT COVERED BY THE WARRANTY.
REPLACING THE SAND
Disassemble the drain (5) and let the water flow out.
Remove the sand or use the Sandvak system.
The sand in the filter must be changed every 5 years.
TROUBLE SHOOTING
Pump will not prime
1.
.
3.
4.
5.
6.
7.
Motor does not turn
1.
2.
3.
30V - 1.4 A
4.
5.
30V - .0 A
6.
30V - .55 A
Low flow-high filter pressure
1.
30V - 4. A
.
Low flow-low filter pressure
1.
2.
3.
4.
Noisy pump
1.
.
3.
WARRANTY
Pentair Water is not responsible for transport damage.
In case of damage notify carrier immediately.
Warranty period:
1 year starting from the production date.
3
No water in strainer pot
Strainer pot is not tight
Damage lid O-ring
Water level is below skimmer
Strainer basket or skimmer basket is clogged
Closed valve in piping system
Air leak in suction line
Power switch is off
Circuit breaker has tripped
Pump is off-mode of a timer controlled circuit
Motor terminal connections are incorrect
Motor shaft is locked by bad bearing
Impeller is locked by debris
Filter is dirty
Restriction in return line
Strainer basket or skimmer basket is clogged
Clogged impeller
Air leak in suction line
Restriction in suction line
Air leak in suction
Foreign matter in pump housing
Cavitation
ENGLISH