4
Installation
Warning
Interference due to electromagnetic sources is liable to
cause sudden compensatory movements of the axis.
Follow the installation procedure below in order to pre
vent this electromagnetic interference.
Connect the earth connection on the left−hand side of
the housing with low impedance (short cable with
large cross−sectional area) to the earth potential, if the
axis interface is not attached to an earthed machinery
frame.
Do not lay any axis interface cables, CP cables,
measuring system cables or proportional directional
control valve cables near or parallel to cables with high
interference levels.
Use only original cables. Attach the plug with the help
of the union nut, so as to avoid any unintentional
slackening caused by oscillation etc.
Seal any unused connectors with the protective caps
provided. Only then is the IP65 type of protection en
sured.
16