Elpro 37
GB
ELECTRONIC BRAKE FUNCTION
ATTENTION:
!
In cases a motor with mechanical brake is used or a control board ELPRO 10 is replaced, the dip-switch - A N° 12 has to be in OFF.
To enable the electronic brake function set the dip-switch - A N° 12 in ON and adjust the electronic brake
intensity by the selector in the figure.
The factory preset adjustments are suitable for most installations.
For a more precise regulation of the electronic brake, it is possible to set up various braking parameters by
following the advanced instructions bellow.
ADVANCED INSTRUCTIONS FOR THE ELECTRONIC BRAKE
ATTENTION:
!
the electronic brake is to be enabled by putting the dip-switch - A N° 12.
Function
Braking time:
Additional stop time
after braking
when safety devices
are activated:
Electric lock:
or courtesy lamp:
SINGLE - THREE PHASE ELECTRONIC CONTROL BOARD
SLIDING GATE AUTOMATIC SYSTEMS WITH OR WITHOUT LIMIT SWITCHES
Description
Description
To adjust the braking duration put the dip-switch - B N° 1 in ON and set the
braking time by trimmer T.FUN.
Once the calibration of braking duration is completed put all dip-switches
- B in OFF.
To set the additional stop time after braking put the dip-switch B N° 2 in ON
and adjust the stop time by mean of trimmer T.FUN.
Once the calibration of additional stop time is completed put all dip-switches
- B in OFF.
N.W.: this function is enabled and adjustable even if the electronic brake
is disabled. It allows more time for the gate to reverse the travel
direction when safety devices as photocells or sensitive edges are
engaged, so as proper reverse movement is achieved, especially for
single-phase motors where high inertia is involved.
For setting working time of the electric lock or courtesy lamp connected to
the 14-15 outputs, put the dip-switch - B N° 3 in ON and adjust the working
time by mean of trimmer T.FUN.
In this mode, the trimmer T.FUN enables you adjust electric lock working time
from 0 s to 5 s on the first half of trimmer travel. On the second half of trimmer
travel it allows you to connect a relé to 14-15 outputs for a courtesy lamp
working time control, adjustable from 30 s to 5 min.
Once the electric lock or courtesy lamp working time is set, put all
dip-switches - B in OFF.
14 15
12 Vac power supply output
for electric lock 15 VA max
or relè for courtesy lamp control
WITH ELECTRONIC BRAKE FOR
15
Dip-switch setting and LED indication of functions
DIP-SWITCH - A
ON
OFF
1 2 3 4 5 6 7 8 9 10 11
1 2
3
4 5
ELECTRONIC BRAKE
INTENSITY
Dip-switch and trimmer of functions
Operations
I
II
T.FUN
0 s - 2 s
DIP-SWITCH - B
ON
OFF
1
2 3 4
Operations
I
II
T.FUN
0 s - 3 s
DIP-SWITCH - B
ON
OFF
2
1
3 4
Operations
I
II
T.FUN
5 s 30 s
DIP-SWITCH - B
ON
OFF
1 2
3
4
0 s 5 min
ON
OFF
12
III
DIP-SWITCH - B
ON
OFF
1 2 3 4
III
DIP-SWITCH - B
ON
OFF
1 2 3 4
III
DIP-SWITCH - B
ON
OFF
1 2 3 4